Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > Vendor Forums > Aqua Digital > GHL Profilux Info & Support

 
 
Thread Tools Display Modes
  #1  
Old 08-27-2008, 10:46 PM
Aqua-Digital's Avatar
Aqua-Digital Aqua-Digital is offline
Member
 
Join Date: Jul 2007
Location: Ottawa
Posts: 3,272
Aqua-Digital is on a distinguished road
Default

Best to email me at sales@aqua-digital.com

it is always hard supporting second hand units and we could be going back and forth for a while on the board.
  #2  
Old 08-27-2008, 11:01 PM
Jason McK's Avatar
Jason McK Jason McK is offline
Member
 
Join Date: Mar 2003
Location: Ladner,BC
Posts: 3,032
Jason McK is on a distinguished road
Default

E-mail Sent

J
__________________
My old Tank Shut down Jan 2011
New 220G build about to start
  #3  
Old 09-06-2008, 04:15 AM
Jason McK's Avatar
Jason McK Jason McK is offline
Member
 
Join Date: Mar 2003
Location: Ladner,BC
Posts: 3,032
Jason McK is on a distinguished road
Default

Michael, Just wanted to thank you for your support on my Temperature probe issue. Spencer at Progressive Reef hooked me up with a new probe and all is right in the world now.

Thanks Again
Jason
__________________
My old Tank Shut down Jan 2011
New 220G build about to start
  #4  
Old 09-06-2008, 12:40 PM
Aqua-Digital's Avatar
Aqua-Digital Aqua-Digital is offline
Member
 
Join Date: Jul 2007
Location: Ottawa
Posts: 3,272
Aqua-Digital is on a distinguished road
Default

Glad to be assistance and thanks to Spenser at progressive reef in BC for helping you get up and running.
  #5  
Old 09-10-2008, 05:48 AM
Jason McK's Avatar
Jason McK Jason McK is offline
Member
 
Join Date: Mar 2003
Location: Ladner,BC
Posts: 3,032
Jason McK is on a distinguished road
Default

Sorry Michael, Have another one for you

I picked up a new temp probe and it has been working perfectly. Today I added the extention cable to the temp probe.
Without the extension temp was reading 79.4
I followed the extension cable instruction as per the latest operator instructions.
1)entered the extension mode without the extesion cable attached (probe was in the tank in the same spot it would be when the cable gets added)
2)press return and wait
3) controller say Change
4) add the extension cable and press return
5) wait and then save
My temp was then reading 74.2
in order to correct this I calibrated the sensor with the extension cable and the temp control returned to 79.5

Have I performed the procedure incorrectly?

Thanks
Jason
__________________
My old Tank Shut down Jan 2011
New 220G build about to start
  #6  
Old 09-10-2008, 12:49 PM
Aqua-Digital's Avatar
Aqua-Digital Aqua-Digital is offline
Member
 
Join Date: Jul 2007
Location: Ottawa
Posts: 3,272
Aqua-Digital is on a distinguished road
Default

Hi

You need to add the cable first as you found I think from reading your thread

Hope all clear now
  #7  
Old 09-10-2008, 01:46 PM
Jason McK's Avatar
Jason McK Jason McK is offline
Member
 
Join Date: Mar 2003
Location: Ladner,BC
Posts: 3,032
Jason McK is on a distinguished road
Default

Um that is not how the instructions read.
The controller prompts you to change/add the cable

J
__________________
My old Tank Shut down Jan 2011
New 220G build about to start
 


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 02:11 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.