#1
|
||||
|
||||
![]() Just got a refractometer, no instructions, not sure how to use it. I get a reading of 1.026 on my hydrometer and get 4 on my refractometer. I was told to multiply that number by 4 and that would give me my SG? If that's the case I'd be sitting at 1.016?
Here is a link to a meter that is almost identical to mine. http://www.sciencefirst.com/vw_prdct..._mdl_cd=78-620 Last edited by Tigerarmy; 08-23-2008 at 06:12 AM. Reason: added a link |
#2
|
||||
|
||||
![]() which model or brand... mine reads the salinity without doing any math.
But typically, just have to calibrate it with pure water to get "1" then read with tank water...
__________________
![]() |
#3
|
|||||
|
|||||
![]() Ok so typically with most refractometers you have SG running down the left side of the scale when you look through, and salinity running down the right.
You should not be getting a reading of "4" that would mean you hardly. Test it with RODI water or bottled water would work and make sure that the reading is either 1.000 SG or 0 salinity. If it isn't use the little screwdriver to move the blue line to that mark. Then do your test making sure you have enough water in the "chamber" and the lid is down tight enough that the water covers the blue grid of the chamber. Not sure about multiplying by 4. Never heard of that. Hope this helps ![]()
__________________
Christy's Reef Blog My 180 Build Every electronic component is shipped with smoke stored deep inside.... only a real genius can find a way to set it free. |
#4
|
||||
|
||||
![]() It only goes up to 28% and it has no salinity on the left hand side. It does zero out, and I get the same reading of 4.
|
#5
|
|||||
|
|||||
![]() I'd return it, its not going to do anything for you as most SW tanks need a salinity of 28-32ppt.
I don't think its a salinity refractometer. Seems kind of odd to me that you don't have the full scale on it.
__________________
Christy's Reef Blog My 180 Build Every electronic component is shipped with smoke stored deep inside.... only a real genius can find a way to set it free. |
#6
|
|||||
|
|||||
![]() Furthermore, if you do end up getting a refractometer more appropriate for a saltwater tank don't use RODI, distilled water, or the water provided with the refractometer to calibrate it. Spend the extra 4 or 5 bucks and get some of the PinPoint 53.0 mS Calibration Solution so you can ensure more reliable readings in the range that you will actually be running your tank.
__________________
SPS Dedicated 24x24x20 Trimless Tank | 20 g Sump | Bubbble King Mini 160 Protein Skimmer w/ Avast Swabbie | NP Biopellets in TLF Phosban Reactor | ATI Sunpower 6 x 24W T5HO Fixture | EcoTech Vortech MP20 | Modified Tunze Nanostream 6025 | Eheim 1260 Return Pump | GHL Profilux Standalone Doser dosing B-Ionic | Steel Frame Epoxy Coated Stand with Maple Panels embedded with Neodymium Magnets "Mens sana in corpore sano" |
#7
|
||||
|
||||
![]() It is a salinity refractometer. I got it from work. It's used for measuring salinity in water that comes out of oil wells.
|
#8
|
||||
|
||||
![]() It's not the right kind of refractometer, the scale is way to big. Seawater averages 35 parts per thousand which would be 3.5%. That is equivalent to 1.0265 SG.
I'm not sure if that will measure the refractive index of seawater correctly though. It should be close enough if you keep it in between 3% and 4% but keep in mind that 3% is about 1.023 and 4% is about 1.030 so you may be better off with something that is more precise. |
#9
|
||||
|
||||
![]() The refracto I got has lines in between 3 and 4.Is there a mathmatical equation I can use to find out SG from ppt?
|
#10
|
||||
|
||||
![]() Quote:
The refractive index of 35ppt seawater is the same as a 36.5ppt solution of sodium chloride. You can get a seawater equivalent reading by multiplying your measurement by .96 Take the number you get and refer to table 3 in this article: http://www.reefkeeping.com/issues/2004-06/rhf/index.php |