Old 04-05-2008, 08:30 PM
Richard_Dicosimo Richard_Dicosimo is offline
Member
 
Join Date: Dec 2004
Location: Calgary
Posts: 298
Richard_Dicosimo is on a distinguished road
Send a message via MSN to Richard_Dicosimo
Default

im not certain but im sure that i read your ro unit will work better with cold water then hot so dont tap your hot water line.

Richard
Reply With Quote
  #2  
Old 04-05-2008, 08:46 PM
Gools's Avatar
Gools Gools is offline
Member
 
Join Date: May 2004
Location: Vernon
Posts: 520
Gools is on a distinguished road
Default

RO membranes are suppose to produce better around 77degrees water temp. I'm getting major condensation on all my RO lines, which has never happened before, so my water is very cold, which will cause you to lose performance. Right now I am getting around 80 psi to my membrane.
Reply With Quote
  #3  
Old 04-05-2008, 10:09 PM
KrazyKuch's Avatar
KrazyKuch KrazyKuch is offline
Member
 
Join Date: Dec 2004
Location: Calgary S.W
Posts: 656
KrazyKuch is on a distinguished road
Send a message via MSN to KrazyKuch
Default

Correct they work best in that 25 degree Celcius temp range and the last time I checked the temp of the water coming out of my tap it was like around 16 degree's celcius
__________________
500G Mixed Reef



__________________________________
Electrician, Electronics Technician, I can help with any electrical questions you might have!!
__________________________________

Kevin
Reply With Quote
  #4  
Old 04-05-2008, 10:26 PM
Black Phantom's Avatar
Black Phantom Black Phantom is offline
Member
 
Join Date: Feb 2006
Location: Calgary
Posts: 331
Black Phantom is on a distinguished road
Default

This might not work for everyone but I run my supply line through my sump.Being that I heat the water for the tank I figured why not use it. I also make sure I do a five minute flush of the membrane once a week. It seams to add to the life of my RO.
__________________
250 gal display tank plumbed directly to my wallet
Reply With Quote
  #5  
Old 04-05-2008, 11:09 PM
Gools's Avatar
Gools Gools is offline
Member
 
Join Date: May 2004
Location: Vernon
Posts: 520
Gools is on a distinguished road
Default

I like the sump idea, only problem is the distance from my RO to sump, would have to travel on the ceiling, then have alot of tubbing in the sump. Would I lose alot of pressure running 50 feet or more of tubing before the water even hits the RO unit?
Reply With Quote
  #6  
Old 04-06-2008, 02:49 AM
littlesilvermax's Avatar
littlesilvermax littlesilvermax is offline
Member
 
Join Date: Oct 2004
Location: Winnipeg
Posts: 779
littlesilvermax is on a distinguished road
Default

Quote:
Originally Posted by Gools View Post
I like the sump idea, only problem is the distance from my RO to sump, would have to travel on the ceiling, then have alot of tubbing in the sump. Would I lose alot of pressure running 50 feet or more of tubing before the water even hits the RO unit?
I tried it with 1/4 RO line, lost a lot of pressure.

I now have 100 feet of 3/8 RO line ($12) and run it in a coil in the sump. It cools my tank and heats the water used for RO. My TDS went down, my fan over my sump runs a lot less, all good stuff.

I highly recommend it.
__________________
250 BB Starphire SPS, clams, & zoos
3 x 250 DE, IC 660 W/T5s
OM 4-way, Hammerhead Pump
Calcium, Kalk, RO filters, magnesium, Excellent prices
Reply With Quote
  #7  
Old 04-06-2008, 03:49 AM
Skimmerking's Avatar
Skimmerking Skimmerking is offline
acanthastrea freak
 
Join Date: Jun 2002
Location: Virden, Manitoba
Posts: 5,690
Skimmerking is on a distinguished road
Send a message via ICQ to Skimmerking Send a message via MSN to Skimmerking
Default

Nigel you can always get a heater joint that attaches to your water line before it goes to your membrane. that hook on the copper pipe and its on a gauge to tell you how warm you want the water , works really good i havent tried one yet thou i may once i get back from over sea........
__________________
180 starfire front, LPS, millipora
Doesn't matter how much you have been reading until you take the plunge.
You don't know as much as you think.
Reply With Quote
  #8  
Old 04-06-2008, 02:25 PM
Gools's Avatar
Gools Gools is offline
Member
 
Join Date: May 2004
Location: Vernon
Posts: 520
Gools is on a distinguished road
Default

Quote:
Originally Posted by littlesilvermax View Post
I tried it with 1/4 RO line, lost a lot of pressure.

I now have 100 feet of 3/8 RO line ($12) and run it in a coil in the sump. It cools my tank and heats the water used for RO. My TDS went down, my fan over my sump runs a lot less, all good stuff.

I highly recommend it.
how much pressure did you lose after running the 100 feet of 3/8 line?
Reply With Quote
  #9  
Old 01-05-2009, 04:36 PM
JDigital's Avatar
JDigital JDigital is offline
Member
 
Join Date: May 2008
Location: Airdrie
Posts: 2,795
JDigital is on a distinguished road
Send a message via MSN to JDigital
Default

Quote:
Originally Posted by KrazyKuch View Post
Correct they work best in that 25 degree Celcius temp range and the last time I checked the temp of the water coming out of my tap it was like around 16 degree's celcius
Agreed, Definitely needs to be warm... There is a build thread I was watching on another forum, and the guy is in colorado and his RO in line was sooo cold that his RO was produing VERY little water... Was more of a drip that a constant flow.. I think it took him close to a full week to fill 140G tank.
__________________
180G Office Reef. Started Sept 2012 http://www.canreef.com/vbulletin/showthread.php?t=88894

62G Starfire Reef. Started Jan 2013 http://www.canreef.com/vbulletin/showthread.php?t=89988
Reply With Quote
  #10  
Old 01-05-2009, 05:35 PM
Black Phantom's Avatar
Black Phantom Black Phantom is offline
Member
 
Join Date: Feb 2006
Location: Calgary
Posts: 331
Black Phantom is on a distinguished road
Default

Since this last came up I have taken the line out of my sump. It was just too hard to keep the tank temp up. I looked around for a constant heat supply and decided that my MH ballast would work just fine. My ballasts have the metal fins for cooling. I just ran the water line back and forth under the ballasts. I'm not sure how much my line temp has risen but it's definately warmer to the touch. And it keeps my ballasts a little cooler as well so thats a bonus. Of course it only works during the day but what the heck, it's free heat.
__________________
250 gal display tank plumbed directly to my wallet
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 03:25 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.