Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > DIY

Reply
 
Thread Tools Display Modes
  #21  
Old 03-21-2008, 04:11 AM
Trigs Trigs is offline
Member
 
Join Date: Mar 2008
Location: richmond
Posts: 218
Trigs is on a distinguished road
Default

Quote:
Originally Posted by mark View Post
Trigs, try a elbow pointing down in your overflow box. Cap the pipe above the tee on the outside, then starting with a small drill slowly go larger until the level in the overflow becomes steady and the drain quiets down (can also use a air valve). Once tuned, the air your pulling through the drain is at a minumun, you'll still get some gurgling but that's the nature of this type of standpipe.

For zero gurgling all I know of is the Herbie style but to be safe, they require two holes for drains.
how will i get the elbow to connect?
__________________
35gallon, skimz 181, aqua controller l3, AI sol blue w/ controller. reef to be
Reply With Quote
  #22  
Old 03-21-2008, 06:49 AM
chevyjaxon's Avatar
chevyjaxon chevyjaxon is offline
Member
 
Join Date: Feb 2008
Location: Edmonton
Posts: 309
chevyjaxon is on a distinguished road
Default

simple you want to slow down the waterflow to the sump a little this is what you do, put a ball or gate valve at the bottom of your stand pipe have it below the water line and then adjust it just until it stops gurgling. worked for me!
__________________
always just 2cents until im broke
Reply With Quote
  #23  
Old 03-21-2008, 07:37 AM
mr_alberta's Avatar
mr_alberta mr_alberta is offline
Member
 
Join Date: Apr 2003
Location: Edmonton, AB (University Area)
Posts: 2,506
mr_alberta is on a distinguished road
Default

That's not the best idea unless you have a backup drain otherwise one day your drain will plug and you'll come home to an empty sump and wet floor.
__________________
32"x32"x20" Cube-ish tank
Reply With Quote
  #24  
Old 03-21-2008, 07:43 AM
Trigs Trigs is offline
Member
 
Join Date: Mar 2008
Location: richmond
Posts: 218
Trigs is on a distinguished road
Default

okay well pretty much
what i have is a overflow to a T the pipe goes up to a cap with a air hole then down to a 90 degree into a straight pipe to a ball valve then to another 90 to my sump with a micron bag over
__________________
35gallon, skimz 181, aqua controller l3, AI sol blue w/ controller. reef to be
Reply With Quote
  #25  
Old 03-21-2008, 12:48 PM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

Quote:
Originally Posted by Trigs View Post
how will i get the elbow to connect?
http://www.flexpvc.com/cart/agora.cg...-Elbows-90-MPT

Not sure of your bulkhead size but they're easy enough to find (I bought some 1" fr Rona)
Reply With Quote
  #26  
Old 03-22-2008, 08:52 AM
Trigs Trigs is offline
Member
 
Join Date: Mar 2008
Location: richmond
Posts: 218
Trigs is on a distinguished road
Default

Quote:
Originally Posted by Whatigot View Post
really easy cheap fix that works is to cut a length of flexible airline tubing and feed one end down into the overflow and leave the other out and free in the air.
This will greatly increase the airflow and mitigate a lot of the gurgling.
try it and see.
free in the air as in out the top by the over flow? like out the cap?
__________________
35gallon, skimz 181, aqua controller l3, AI sol blue w/ controller. reef to be
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 06:42 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.