1st guage tank pressure
2nd guage supply pressure
then the soleniod
then it looks like the needle valve.....for gas input to the reactor
there should be a clamp of sorts on the in flow line from aquarium to the reactor...this regulates water input
Reply With Quote
  #2  
Old 03-02-2008, 11:08 PM
adidas's Avatar
adidas adidas is offline
Member
 
Join Date: Dec 2004
Location: calgary
Posts: 1,098
adidas is on a distinguished road
Send a message via MSN to adidas
Default

Quote:
Originally Posted by fencer View Post
1st guage tank pressure
2nd guage supply pressure
then the soleniod
then it looks like the needle valve.....for gas input to the reactor
there should be a clamp of sorts on the in flow line from aquarium to the reactor...this regulates water input
thanks. right now the tank pressure is just over 5 MPa which would be 750psi if i'm right. its a 10 pound tank. 1 MPa = 150psi, the other gauge i had about 0.1 which is 15psi. so i just need to adjust the needle valve then. think i have it figured out

Last edited by adidas; 03-02-2008 at 11:41 PM.
Reply With Quote
  #3  
Old 03-03-2008, 12:43 AM
adidas's Avatar
adidas adidas is offline
Member
 
Join Date: Dec 2004
Location: calgary
Posts: 1,098
adidas is on a distinguished road
Send a message via MSN to adidas
Default

hmmm guage says 0.2 and there are absolutely no bubbles... am i leaking co2?
Reply With Quote
  #4  
Old 03-03-2008, 01:15 AM
fencer's Avatar
fencer fencer is offline
Member
 
Join Date: Aug 2007
Location: Ed Ab
Posts: 1,331
fencer is on a distinguished road
Default

My discharge pressure is 20 psi. Your soleniod might be the problem. Open up the needle valve a little more to see if you can get it to bubble in the chamber
Reply With Quote
  #5  
Old 03-03-2008, 03:50 AM
Delphinus's Avatar
Delphinus Delphinus is offline
Member
 
Join Date: Dec 2001
Location: Calgary
Posts: 12,896
Delphinus has a spectacular aura aboutDelphinus has a spectacular aura aboutDelphinus has a spectacular aura about
Send a message via MSN to Delphinus
Default

I'm inclined to think solenoid valve too at this point..
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!
Reply With Quote
  #6  
Old 03-03-2008, 04:04 AM
fencer's Avatar
fencer fencer is offline
Member
 
Join Date: Aug 2007
Location: Ed Ab
Posts: 1,331
fencer is on a distinguished road
Default

Dumb question....is the soleniod plugged in.....sorry had to ask
Reply With Quote
  #7  
Old 03-03-2008, 06:07 PM
adidas's Avatar
adidas adidas is offline
Member
 
Join Date: Dec 2004
Location: calgary
Posts: 1,098
adidas is on a distinguished road
Send a message via MSN to adidas
Default

found the problem!

the needle valve and the solenoid were both clogged up, got them all apart now and cleaning them.
Reply With Quote
  #8  
Old 03-03-2008, 07:29 PM
Pescador's Avatar
Pescador Pescador is offline
Member
 
Join Date: Apr 2002
Location: Calgary, McKenzie Towne
Posts: 447
Pescador is on a distinguished road
Default

If they are plugged up it sounds like they might have had water back up into them. Use should have a check valve between the solenoid and reactor I use two cause I haven't found them to be 100% reliable.
__________________
Brian
____________________________________________
220g inwall 48"x36"x30"
110g mangrove refug/sump
Poison Dart Frog Vivarium
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 06:27 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.