![]() One caveat: I use the older style calcium reactor media (2-3mm particle size). The newer medias tend to be things like really coarse crushed media (like 1/2" - 1" in size), you can run a much lower pH with that kind of media than you can with the smaller stuff. I'm not sure but you might even *need* to run the pH lower with the coarser stuff.
__________________
-- Tony My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee! |
#2
|
|||||
|
|||||
![]() thanks for the help Tony
Its a GEO 612 rector, holds quite a bit of media.ome question, after the solenoid closes, is it normal for the bubble counter to take a few mins to stop? |
#3
|
|||||
|
|||||
![]() Hmmm, I think it's normal for it to be non instant because what's happening is the valve is shut upstream of the needle valve, but there is still residual pressurized CO2 downstream and so however long it takes to reach equilibrium is how long it will take to stop bubbling .. a few minutes does seem sort of long though.. What's your outlet pressure set at? I run mine around 18psi, I found anything less I just couldn't really get a consistent bubble rate (I have a Milwaulkee brand regulator which is reputed to be not really one of the best, so that could be a part of it for me).
__________________
-- Tony My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee! |
#4
|
|||||
|
|||||
![]() hmmm the guage on the right says 5, the one on the left we had at between 0.1 and 0.2. not sure which one is which
Last edited by adidas; 02-29-2008 at 09:05 PM. |
#5
|
|||||
|
|||||
![]() I'm running the same reactor, what is your effluent flow?
Mine is on the high side I think about 200ml/min. Co2 is about 60bpm. PH in the reactor is about 6.8. My Aquamedic regulator is preset at about 18-20psi. I open the needle valve on the reg to get a steady flow and fine tune it with a Redsea needle valve. I'm pretty impressed with the larger media it's only gone down about an inch in 2 months I would have used 1/2 a chamber of the fine stuff in my K2R.
__________________
Brian ____________________________________________ 220g inwall 48"x36"x30" 110g mangrove refug/sump Poison Dart Frog Vivarium |
#6
|
|||||
|
|||||
![]() is psi the guage on the right? mine is at 5.and how do i know what my effluent flow is at?
|
#7
|
|||||
|
|||||
![]() I'm not sure what units 5 and 0.1 would be. The two numbers though, should represent inlet pressure (the pressure on the inlet side of the valve, the tank, basically) and outlet pressure. Tanks are usually around 800psi or so when full. The other pressure unit I know of is kPA (kiloPascal) but I think it's something like 1.5 psi per 10 kPA which means 800psi is something like 5500 kPA.
![]() There's nothing on the guage itself that says what the units are?
__________________
-- Tony My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee! |