#1
|
||||
|
||||
![]() Did he by any chance explain how to correct for temperature with this? The closest I've ever found to a bona fide reference is the table on the back of pinpoint's calibration packets and I bet that doesn't necessarily correspond with SW.
|
#2
|
|||||
|
|||||
![]() with the temperature we run our aquariums at temperature callibration is almost negligable. I saw a chart somewhere once and it's like a 2% difference. (ph 8.302 instead of 8.297)
__________________
Everything I put in my tank is fully dependant on me. |
#3
|
|||||
|
|||||
![]() Here is a schematic I just did up for an Orp interface
![]()
__________________
500G Mixed Reef ![]() __________________________________ Electrician, Electronics Technician, I can help with any electrical questions you might have!! __________________________________ Kevin Last edited by KrazyKuch; 02-15-2008 at 04:29 PM. |
#4
|
|||||
|
|||||
![]() does the orp interface work the same with a pH probe too? only the calibration points would be separate?
__________________
Everything I put in my tank is fully dependant on me. |
#5
|
|||||
|
|||||
![]() Yeah thats basically how all probes work.....All you have to do is amplifi the signal to a stat that is easily readable from your controller then it's a matter of figuring out how the signal gets converted into the proper reading.....for PH after it's amplified 1 millivolt will stand for a ph of 1 a 10 millivolt signal stands for a ph of 10....If you want I can get the calculations for the orp!
__________________
500G Mixed Reef ![]() __________________________________ Electrician, Electronics Technician, I can help with any electrical questions you might have!! __________________________________ Kevin |
#6
|
|||||
|
|||||
![]() what's that on the far lefthand side that was cut off in the schematic labeled "X1"?
What about having software callibration? Which pots would be cut out for software callibration? (for example, put probe in ph 7 solution, press button. put ph probe in ph 10 solution, press button)
__________________
Everything I put in my tank is fully dependant on me. |
#7
|
|||||
|
|||||
![]() The X1 in that schematic is the BNC connector.....basically that schematic is for orp...I have another for PH if you want it, well basically you can remove the 2 variable resistors and thats all the one that is on the orp is a set it once and never again kinda dealy...
__________________
500G Mixed Reef ![]() __________________________________ Electrician, Electronics Technician, I can help with any electrical questions you might have!! __________________________________ Kevin |