Dave I checked that earlier and its all clear. I have a flow meter on the unit and it drops off when the air builds up. I'll take a pic for everyone to show.
Quote:
Originally Posted by wickedfrags.com View Post
There is supose to be air in there (usually the top 1") but you should still have effluent.

Check the efffluent tubing to the tank and see if it clogged (this happens on the intake as well). Try blowing out the tubing, and if the air does not pass through, what I do is use a long piece of aircraft wire of the correct diameter and snake the tubing (you could also replace the tubing). You should see the stuff that comes out!

It could also be pressure due to aragonite breakdown as noted below. Let us know what you find and if it is not fixed post a pic for us.

WF
__________________
Mike

150g reef, 55g sump, T5's, Vertech 200A, Profilux III - German made is highly over rated, should just say Gerpan made.

Reefkeeper - individual obsessed with placing disturbing amounts of electricity and seawater in close proximity for the purpose of maintaining live coral reef organisms.
Reply With Quote
  #2  
Old 01-29-2008, 06:21 PM
wickedfrags's Avatar
wickedfrags wickedfrags is offline
Member
 
Join Date: May 2007
Location: Mississauga
Posts: 1,319
wickedfrags is on a distinguished road
Default

A flow meter for the water effluent right? Located after the second chamber and controlled by a needle valve? Ya we need a pic

Quote:
Originally Posted by andestang View Post
Dave I checked that earlier and its all clear. I have a flow meter on the unit and it drops off when the air builds up. I'll take a pic for everyone to show.
__________________
I'm out.
Reply With Quote
  #3  
Old 01-29-2008, 06:28 PM
Delphinus's Avatar
Delphinus Delphinus is offline
Member
 
Join Date: Dec 2001
Location: Calgary
Posts: 12,896
Delphinus has a spectacular aura aboutDelphinus has a spectacular aura aboutDelphinus has a spectacular aura about
Send a message via MSN to Delphinus
Default

Do you have a separate feed pump or are you relying on the siphon created by the recirc pump? I could never get a steady flowrate using just the recirc pump. I guess this makes sense because the resistance will probably change as the media gets used up.

Anyhow my guess is if the media is a year old then this is very likely the culprit. A year is not a bad run. Seems to me an air bubble on its own shouldn't cause the pump to vapor lock (if you think about it, the pump should just suck that air bubble, shred it into a million little bubbles that trickle up through the media). I think it's more that the water has nowhere to go.
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 01:32 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.