From PFO's site. (HQI for PFO is the SA)

Pulse Start or HQI style Ballast?

The standard ballast has a transformer and capacitor in the circuit. The HQI ballast has a transformer, capacitor, and an igniter in the circuit. The pulse start has a transformer, capacitor, and an igniter in the circuit.



The European lamps work best with an igniter in the circuit.(Ushio, AB, Radium). The HQI ballast generally simulates the European ballast closer than the pulse start ballast does. However, the pulse start ballast is a lot less expensive than the HQI ballast. If you are on a budget and want the European lamps than get a pulse start ballast to ensure these lamps will fire. However, the light output will probably be reduced.



As a general rule we do not recommend the pulse start ballast on European bulbs. If you are trying to make a decision on running a European lamp on a standard ballast or a pulse start ballast, choose the pulse start ballast.
__________________
Brad
Reply With Quote
 


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 03:14 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.