![]() The amount of flow that you can get through any particular pipe is dependent on the head pressure of the water above it. It is actually the reason that Herbie works. I can't tell you how much flow you'll get in your particular situation.
You'll just have to build it to find out! JL purchases those valves from Corix. Corix sold a 1.5" gate valve to me for $35...(but I was quite a regular customer there!)
__________________
400 gal reef. Established April, 2007. 3 Sequence Dart, RM12-4 skimmer, 2 x OM4Ways, Yellow Tang, Maroon Clown (pair), Blonde Naso Tang, Vlamingi Tang, Foxface Rabbit, Unicorn Tang, 2 Pakistani Butterflies and a few coral gobies My Tank: http://www.canreef.com/vbulletin/showthread.php?t=28436 |
#2
|
|||||
|
|||||
![]() For flow amount get in touch with Skimmin on this board.
He's in the process of setting up a tank with a Dart as a return and has been experimenting with Herbies. If not glued up might be able to duplicate your setup for some feedback. |
#3
|
|||||
|
|||||
![]() Yes, I have been following his build. I think I will have to just give it a shot though and see how the herbie works on my tank. I have not glued anything yet because I want to have all the plumbing including the closed loop dry fitted first, so people can look at it and give me advice.
|
#4
|
|||||
|
|||||
![]() Quote:
|
#5
|
|||||
|
|||||
![]() Quote:
When you first turn it on, water should fall right to the bottom of the overflow box and go out the primary drain. As you close off the valve, you'll hit a point where the water level in the overflow box starts to rise. You want to dial up the water level as high as possible, short of the emergency drain. My overflow boxes are only 12" deep. I found that I need to keep the water at least 6+" deep to prevent air bubbles being drawn down into the primary when the water falls into the overflow.
__________________
400 gal reef. Established April, 2007. 3 Sequence Dart, RM12-4 skimmer, 2 x OM4Ways, Yellow Tang, Maroon Clown (pair), Blonde Naso Tang, Vlamingi Tang, Foxface Rabbit, Unicorn Tang, 2 Pakistani Butterflies and a few coral gobies My Tank: http://www.canreef.com/vbulletin/showthread.php?t=28436 |
#6
|
|||||
|
|||||
![]() Quote:
|
#7
|
|||||
|
|||||
![]() Quote:
I have 4 separate Herbie overflows in my system and they are all inter-related. Any change to any of them affects the others. Yes, start up with the gate valve wide open. It will be noisy and the water level in the overflow box will be right on the bottom. That will prove to you that you've designed with excess capacity. Next test: Shut the gate valve 100% closed. This will test your emergency overflow. This is the test that will make you nervous as the overflow water level rises up to that emergency level. You need to know for sure that the emergency overflow can take ALL the volume. Be ready to stop the return pump, or open that gate valve fast....just in case. (and make sure that the emergency overflow actually has pipe connected to it!!!!) When you go to fine tune things, you'll find that small changes to the gate valve make a difference. It also takes a while for the system to equalize after a change, so adjust slowly.
__________________
400 gal reef. Established April, 2007. 3 Sequence Dart, RM12-4 skimmer, 2 x OM4Ways, Yellow Tang, Maroon Clown (pair), Blonde Naso Tang, Vlamingi Tang, Foxface Rabbit, Unicorn Tang, 2 Pakistani Butterflies and a few coral gobies My Tank: http://www.canreef.com/vbulletin/showthread.php?t=28436 |
#8
|
|||||
|
|||||
![]() Quote:
Ok that all makes sense but what about getting the refugium herbie and main drain herbie working together? It seems like it would be hard to work on fine tuning both at the same time, especially if you are starting with both wide open. I guess Im just a bit nervous. If it were just the overflow using a herbie, I would feel fine but the refugium one worries me. |
#9
|
|||||
|
|||||
![]() Quote:
Remember, you should be able to flood anything, provided your emergency overflows are in place. If the Herbie valves get really mis-adjusted, then the water just flows down the emergency pipes and makes a lot of noise. You adjust them, and wait for the system to achieve a new steady state. Here's some fun...I won't even attempt to explain this in detail...but I can manipulate the salinity of my system by adjusting the Herbie valve that runs between my small sump and the main sump. Hint: evap water is monitored by a float valve in the main sump. If you can get your head around that one, then you have achieve Herbie mastery!