![]() Can't say nothing about the Herbie as but to listen to Untamed as he's experienced with running one.
For the return you should be able to reduce pipe diameter one size to make a little more manageable after the top Tee, build a manifold (such as like here) to even out flow and with multiple outlet not have a great loss. RC calculator might be a guide. |
#2
|
|||||
|
|||||
![]() Quote:
If you are, you say it should be fine to reduce down to a 1.5" PVC after the first "T"? That may help out a lot actually. In a way...Its kind of a weird situation and heres why... The closed loop pump has a 1.5" outlet. The bulkhead that the return is going through is 2". I figured this is good because I always hear its good to go up a size anyways. So like I said, I figured it would work well if I went from 1.5" at the outlet to 2" right away and then through the bulkhead and used a 2" manifold. As I said though, the 2" manifold is a bit tricky to manage. So your idea to reduce down to 1.5" seems good. Maybe I should just use to reducers right around the bulkhead? So basically the pump goes to the bulkhead at 1.5" and goes through at 2" and then goes back to 1.5". Seems kind of weird but I can't change the 2" bulkhead at this point. Any thoughts??? |
#3
|
|||||
|
|||||
![]() Quote:
Also, if your pump has a 1.5" outlet, you may be better off to keep the rise pipe form sump to tank that size. Increasing the vertical pipe to larger will add more water in the vertical colum, thus more weight. More weight the pump has to lift, the more head pressure the pump will see, the less GPH it will flow. On Horizontal, and bends, larger is better, but not uphill. Just ask any Firefighter. I'd much rather haul the 1.5" hose up 3 storys than the 2.5" Just changing the pipe pump outlet pipe to 2" for the bulkhead will be fine, and I think, would be the best bet Last edited by banditpowdercoat; 10-31-2007 at 04:36 AM. |
#4
|
|||||
|
|||||
![]() Quote:
I do understand what you are saying but there was also a specific reason people increase the pipe size on these pumps I just forget why ![]() I know for sure that Mag pumps should always be plumbed with a size bigger pipe. The manufacturer states that themselves. |
#5
|
|||||
|
|||||
![]() I think you edited your post after and added basically what I was saying but in one sentence instead of a paragraph! LOL
![]() |
#6
|
|||||
|
|||||
![]() Anymore advice for the closed loop? I think I may just stick to going right to 2" stuff right after the output and then stay at 2". Im just unsure about what to use at each outlet? I don't really want to use loc line...
|
#7
|
|||||
|
|||||
![]() I have seensome just cut little pipe pieces, heat the end and squish it to create a nozzle. I went Loc Line with mine mainly because this is my first tank, and I dont know exactly how the water should flow and such. so, 7 1/2" loc line nozzles should give me pretty good adjustability......I hope
![]() |
#8
|
|||||
|
|||||
![]() Quote:
So since I cannot seem to find a 2" Gate Valve in town, you you guys think reducing my overflow return down to 1.5" would be a bad idea? I thought 2" was overkill to begin with, so maybe? I can easily get 1.5" Gate Valves. The return pump is big though (Mag 24) and may need the 2" drains. I really do not know at this point. The other option would be to scrap the whole herbie thing and do a traditional type overflow and return. |