#1
|
|||||
|
|||||
![]() QUESTION: Has anyone noticed a high TDS reading as soon as they turn on their RO/DI units?
I recently noticed my in-line TDS reads 500-1500ppm for a few minutes as soon as my RO/DI turns on! It does gradually drop to 001 ppm after only a couple of minutes. I have the unit connected to an Oceanus Triton top-off controller. Because my RO/DI runs in short bursts, I think my top-off water has been poor. When I actually tested my 55 gal top-off tank with a hand held meter, it had a TDS of 445 ppm ![]() Has anyone else noticed such high initial TDS readings from their systems? Does anyone flush or discard their initial water before collecting it? System: Maxxima Hi-S RO/DI Filter. I recently added a second Hi-S RO unit (120 GPD). All my filters are less than 6 months old. I flush the unit weekly.
__________________
300 gal starphire custom built in pentagon reef (+90 gal sump on Blue Line 100 HD return pump, 210lb LR, Euro-Reef RC250 skimmer, 2x400W MH, 2x28W compacts, 2xTurbelle classic 4002 pumps & Turbelle Stream 6100 on 7095 Multicontroller, running ZEOvit) Livestock Fish: damsels; sailfin, yellow, regal & naso tangs; ocellaris & tomato clowns; lyretail anthias; foxface lo; flame angelfish corals: a few |
#2
|
|||||
|
|||||
![]() It's a known issue but for the life of me I can't remember the term for it.
I don't have an auto top off device, but when I make water for my 5g top off bucket, I hook the system up, let it run for 10-15 minutes, dump that water and then keep the stuff after that. |
#3
|
|||||
|
|||||
![]() I've seen it posted before that there's a TDS rise (TDS creep) with ro/di and auto-topoff.
I've got a float valve hooked to my Aquasafe unit and have tested many times the first couple of ounces (just enough so my meter reads) but never seen it. |