Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #1  
Old 04-26-2007, 03:15 AM
bsyoun bsyoun is offline
Junior Member
 
Join Date: Feb 2007
Location: Calgary, AB
Posts: 12
bsyoun is on a distinguished road
Default

very true.
Reply With Quote
  #2  
Old 04-26-2007, 03:17 AM
King of the Sea's Avatar
King of the Sea King of the Sea is offline
Member
 
Join Date: Apr 2007
Location: Keowna BC
Posts: 33
King of the Sea is on a distinguished road
Default

think need two overflows?
__________________
Spent the rent on fish
Reply With Quote
  #3  
Old 04-26-2007, 03:18 AM
andsoitgoes's Avatar
andsoitgoes andsoitgoes is offline
Member
 
Join Date: Sep 2006
Location: Secret Location
Posts: 433
andsoitgoes is on a distinguished road
Default

I have a 600gph overflow being pushed back by a MJ 1200 to about 4' head - never a problem. The overflow will adjust to the speed of the return
Reply With Quote
  #4  
Old 04-26-2007, 03:34 AM
bsyoun bsyoun is offline
Junior Member
 
Join Date: Feb 2007
Location: Calgary, AB
Posts: 12
bsyoun is on a distinguished road
Default

A second overflow box would provide extra insurance, in case the siphon breaks on the other box, but I don't think this is very common if the overflow is designed/set-up properly.

If the noise from your overflow gets too loud, you can set up a Durso standpipe (http://www.dursostandpipes.com/).

Last edited by bsyoun; 04-26-2007 at 03:37 AM.
Reply With Quote
  #5  
Old 04-26-2007, 03:30 AM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

Should find a pump factoring in head loss that will match to your overflow or the flow you're aiming for (eg pump rating - head loss = overflow rating). Unless you have plans for teeing off the return for some other function (Ca reactor, phosban reactor or such) you're really just buying a bigger pump for nothing.

If planning on relying on the return pump for circulation only, 600 gph on a 100g not that much turn over. If the return pump is only to cycle water through the sump and have powerheads, streams or a closed loop for display, 600gph should be enough. Haven't played with hang on overflows but would imagine more you push through them, noisier they may be.

Should be using a ball valve and unions though to allow to remove pump for maintanence or repair if pump's to be external.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 04:39 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.