  #1  
Old 02-25-2007, 06:24 PM
Fish's Avatar
Fish Fish is offline
Member
 
Join Date: Jul 2004
Location: Okotoks, AB
Posts: 724
Fish is on a distinguished road
Default

Well, I have almost everything I need except for a 1" union and maybe a little extra pvc pipe.
During the warm weather I put another coat of paint on the stand. I also drilled holes in the wooden tops and painted them with a marine resistant paint to try and preserve them.









Once I have all the plumbing pieces I am going to sand them down and paint them with krylon fusion.
There is this little voice of reason in my head and is telling me that I shouldn't have chosen black and the color of my stand... I am usually pretty anal about keeping things clean - but I've never had to account for every single drop of spilled water before.


- Chad
__________________
Returning to the hobby after an eight year absence.
Reply With Quote
  #2  
Old 02-25-2007, 07:21 PM
AndyL's Avatar
AndyL AndyL is offline
Member
 
Join Date: Oct 2004
Location: Beiseker
Posts: 900
AndyL is on a distinguished road
Send a message via MSN to AndyL
Default

Gotta comment for a second...

Watch that plumbing for your closed loop - hard plumbing like that without any flex/vibration isolation in the plumbing - can lead to tank breakage. I snapped 2 tanks with plumbing that wasn't dissimilar to that. (and the harmonic vibrations don't help with keeping noise down)

Andy
__________________
By reading, replying to, commenting about, or in any way accessing the material in this post; including but not limited to storing in a database, retrieving from a database, viewing in a web browser, including it in or making a reference to it in a legal document, or accidentally glancing at it you agree to send me $100.
Reply With Quote
  #3  
Old 02-25-2007, 08:30 PM
Fish's Avatar
Fish Fish is offline
Member
 
Join Date: Jul 2004
Location: Okotoks, AB
Posts: 724
Fish is on a distinguished road
Default

Andy are you talking about the photos? The plumbing you see in the first pic is one of my return pipes and they will just hang over the top of the tank.

I do realize that I need to brace the pipe coming from the closed loop so that all that weight isn't sitting on the bulkhead. Because the glass is 1/2" thick, I'm not going to break the tank unless I really reefed on it (fortunately I have gotten in the habit of overbuilding tanks whenever there are bulkheads involved)... but a crack in that bulkhead would be equally catastrophic and would drain the tank down 2/3 of the way.
Thanks,

- Chad
__________________
Returning to the hobby after an eight year absence.
Reply With Quote
  #4  
Old 02-25-2007, 08:41 PM
AndyL's Avatar
AndyL AndyL is offline
Member
 
Join Date: Oct 2004
Location: Beiseker
Posts: 900
AndyL is on a distinguished road
Send a message via MSN to AndyL
Default

That's exactly what I'm talking about... Even with 1/2" glass I'd be concerned - with such a short length of plumbing 'feeding' the pump - there's going to be a significant transfer of vibes/resonance from the pump to the bulkhead (thus to the glass). Temporarily plumb it in - fill the tank and run it - put your hand on the pane that feeds, and on the pump... You'll feel the vibration through both.

When you've got a couple feet (like often seen on big tanks) between the bulkhead and pump - that few feet of pvc acts as a vibration isolator; but in your setup there's nothing really there to isolate - you've got less than 6" which isn't enough 'free space' to have the same effect... I did the same as you have on my 7g bf even with careful plumbing of the closed loop - the vibration of the mag 3 alone was enough to snap the back glass corner to corner.

A small hunk of flex between the 90 and the union or between the union and the pump would go a long way.

Just my .02, not trying to criticize, just pointing out something I've learned in the past.
__________________
By reading, replying to, commenting about, or in any way accessing the material in this post; including but not limited to storing in a database, retrieving from a database, viewing in a web browser, including it in or making a reference to it in a legal document, or accidentally glancing at it you agree to send me $100.
Reply With Quote
  #5  
Old 02-25-2007, 08:56 PM
Delphinus's Avatar
Delphinus Delphinus is offline
Member
 
Join Date: Dec 2001
Location: Calgary
Posts: 12,896
Delphinus has a spectacular aura aboutDelphinus has a spectacular aura aboutDelphinus has a spectacular aura about
Send a message via MSN to Delphinus
Default

Western Pump is a good place to get the spa flex tubing. I second Andy's comments, always use short lengths of spa flex or even just vinyl tubing between bulkhead and pump, even if the vibrations aren't enough to crack glass, the flex pipes will absorb the vibrations and lessen that "hum" sound you'll get.
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!
Reply With Quote
  #6  
Old 02-25-2007, 10:10 PM
Fish's Avatar
Fish Fish is offline
Member
 
Join Date: Jul 2004
Location: Okotoks, AB
Posts: 724
Fish is on a distinguished road
Default

Oh I see, I thought you were talking about closed loop plumbing. What you are looking at in the photo is the sump and sump return pump. Luckily the closed loop and sump return plumbing to the display tank is each about 4' in length, plastic, and full of fluid (great qualities if you want to isolate vibes!). Unfortunately though I am cramped for space with the sump return pump. As you can see in the photo, the pump is on the very edge, almost hanging off of the stand - and that is after I cut down each of the PVC fittings by half with a hacksaw! There is no room for any tubing from the elbow to the pump (unless I took out the quick release union... I guess I could). Even if I put flex tubing from the bulkhead to the elbow there is so little free space that direction that the flex tubing would have to be so short there wouldn't be enough there to 'flex', the fittings would almost be touching each other.

Great ideas guys, and if there was another way of doing it, I would have. On past tanks I have even used a hosebarb on the sump bulkhead, and hosebarb on the pump, and 6" of hose between the two. It might be a little tough to visualize from the photo, but I don't have any extra room.
On the bright side, there isn't any unsprung weight on the bulkhead. I connected the pump to the bulkhead first and then siliconed and tightened the bulkhead down so that it set in the neutral position without any weight on it....

- Chad
__________________
Returning to the hobby after an eight year absence.

Last edited by Fish; 02-25-2007 at 10:29 PM.
Reply With Quote
  #7  
Old 03-02-2007, 01:33 AM
Fish's Avatar
Fish Fish is offline
Member
 
Join Date: Jul 2004
Location: Okotoks, AB
Posts: 724
Fish is on a distinguished road
Default Update

Well I scrapped the plan to bolt the closed loop pump to the underside of my stand - it would have been nice to be able to tuck it up out of the way, but it would have made it a lot harder to service the pump. Fortunately, I came up with a new plan that I am pretty excited about, despite being short on building materials... and tools.....
and technical skill

This is what it looks like now:



It should look good when it's done though.



Here is a shot of some of the plumbing that I have glued already (you can see both the returns that will come over the top of the tank):




I was actually going to paint the plumbing today but I took my sump tank in to the local glass shop so they could measure and cut a baffle pane for me. They ended up keeping the tank until tomorrow and I can't finish my plumbing measurements and cuts without it.



- Chad
__________________
Returning to the hobby after an eight year absence.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 04:59 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.