Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Product Review and Equipment Forum

Reply
 
Thread Tools Display Modes
  #1  
Old 02-01-2007, 02:14 PM
christyf5's Avatar
christyf5 christyf5 is offline
Staff
 
Join Date: Aug 2001
Location: Nanaimo
Posts: 9,175
christyf5 is on a distinguished road
Default

Is the temp you're getting the reading on the chiller or a thermometer? You may have to check the temp with a normal thermometer and then "calibrate" the chiller to that temperature. I know my chiller was off by a degree or so when I first got it.
__________________
Christy's Reef Blog

My 180 Build

Every electronic component is shipped with smoke stored deep inside.... only a real genius can find a way to set it free.
Reply With Quote
  #2  
Old 02-01-2007, 02:17 PM
muck's Avatar
muck muck is offline
Member
 
Join Date: Mar 2004
Location: Edmonton, AB (West)
Posts: 4,329
muck is on a distinguished road
Default

Maybe the heater has a thermostat that is a bit off. Did you notice if your heater was running off and on before (when it shouldn't have)? Now that the chiller thermostat is controling the heater, maybe that fixed the problem..??

Just thinking out loud here..
Reply With Quote
  #3  
Old 02-02-2007, 02:42 AM
Johnny Reefer's Avatar
Johnny Reefer Johnny Reefer is offline
Member
 
Join Date: May 2005
Location: Victoria, B.C.
Posts: 1,192
Johnny Reefer is on a distinguished road
Send a message via MSN to Johnny Reefer
Default

Quote:
Originally Posted by christyf5 View Post
Is the temp you're getting the reading on the chiller or a thermometer?
Both. Actually three readings. The chiller reads 78/79....I have a pinpoint probe in the sump that is at 78.5....and I have a pinpoint probe in the display tank that reads 77.5.

Quote:
Originally Posted by muck View Post
Maybe the heater has a thermostat that is a bit off. Did you notice if your heater was running off and on before (when it shouldn't have)? Now that the chiller thermostat is controling the heater, maybe that fixed the problem..??

Just thinking out loud here..
I should also mention that in addition to the 300W heater off the chiller I have a 200W heater plugged in as a heater normally would. Whenever I look I never see the 300W heater on and the 200W heater is always on. Both are in the sump.

It's weird. I guess it's doing the job but I never hear it. I'd like to hear the chiller kick in just once, just so I know it's alive.

Cheers,
__________________
Mark.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 03:32 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.