Default Exterior Walls & Weight Question

I'm currently in the process of building a new home and thought it would be cool to build an aquarium into the cantilever (sp) of the dining room. For those of you who don't know these are the box outs seen on the outside of homes that extend beyond the foundation walls.

My conern is that the tank will be exposed to an exterior wall on the back & sides. Is this something I should be concerned about. Heat in the summer & cold in the winter?

Will the weight of a 6 foot tank cause any problems? I would imagine a portion of the weight would fall directly on the foundation wall while a portion would fall on the i-joists on the outside of the wall.

I'm just looking for some feedback from more experienced reefers then I.

Thanks
Reply With Quote
  #2  
Old 10-23-2006, 01:29 AM
Tangman's Avatar
Tangman Tangman is offline
Member
 
Join Date: Jan 2005
Location: Mission, B.C.
Posts: 370
Tangman is on a distinguished road
Default

Quote:
Originally Posted by Josh24 View Post
I'm currently in the process of building a new home and thought it would be cool to build an aquarium into the cantilever (sp) of the dining room. For those of you who don't know these are the box outs seen on the outside of homes that extend beyond the foundation walls.

My concern is that the tank will be exposed to an exterior wall on the back & sides. Is this something I should be concerned about. Heat in the summer & cold in the winter?

Will the weight of a 6 foot tank cause any problems? I would imagine a portion of the weight would fall directly on the foundation wall while a portion would fall on the i-joists on the outside of the wall.

I'm just looking for some feedback from more experienced reefers then I.

Thanks
Sorry, but the cantilever is build for a china cabinet, and is not build to handle the weight of a 6' tank. But if you are just building the house there is no reason the builder couldn't reinforce the cantilever for your purpose
__________________
HAPPY REEF KEEPING !!______________________
Reply With Quote
  #3  
Old 10-23-2006, 01:41 AM
Josh24's Avatar
Josh24 Josh24 is offline
Member
 
Join Date: Jul 2003
Location: Calgary
Posts: 42
Josh24 is on a distinguished road
Default

What suggestions would you have to increase the strength?
The I-joists have to cross the foundation at 90 degrees. I doubt there is anything they could do to increase the strength. After all I-josits are already enginered.

Do you work in the industry Tangman? What are you basing your opinion on?

I guess the real question is would it be any different then having the tank located somewhere else within the house as it would only be supported by i-joists unless you located it over a beam or reinforced the i-joist from below.

What do you suggest

Thanks

Last edited by Josh24; 10-23-2006 at 01:45 AM.
Reply With Quote
  #4  
Old 10-23-2006, 02:58 AM
Chin_Lee's Avatar
Chin_Lee Chin_Lee is offline
Member
 
Join Date: Apr 2002
Location: Surrey, B.C.
Posts: 2,208
Chin_Lee is on a distinguished road
Send a message via MSN to Chin_Lee
Default I joists

I joists are quite strong already and the front of the tank (which will be over the foundation) will be pretty strong. Its the back half of the tank that would be of some concern. If i were you, I would get a couple of 12" radius cement tubes and pour a 2-3' column of cement at each outisde corners of the cantilever. set in the 4x4 or 6x6 post holders before the cement dries, and then support the corners with 4x4 or 6x6 posts.
BTW - that would be an ideal location to build a fish room in the basement underneath your dining room where you can plumb the upstairs tank into a sump in the basement. If this is something you want to consider, i suggest pulling through a couple 1.5" and one or two 1" spa flex pvc tubes through the joists now. Or plumb regular PVC through the space between your exterior wall and gyproc and into the basement.
__________________
____________
If people don't die, it wouldn't make living important.
And why do we fall? So we can learn to pick ourselves up.
Reply With Quote
  #5  
Old 10-23-2006, 04:18 AM
Tangman's Avatar
Tangman Tangman is offline
Member
 
Join Date: Jan 2005
Location: Mission, B.C.
Posts: 370
Tangman is on a distinguished road
Default

What suggestions would you have to increase the strength?
The I-joists have to cross the foundation at 90 degrees. I doubt there is anything they could do to increase the strength. After all I-josits are already enginered.
Yes, they are engineered, but not for point loading ,ie:having all the weight in one spot

Do you work in the industry Tangman? YES What are you basing your opinion on?

I guess the real question is would it be any different then having the tank located somewhere else within the house as it would only be supported by i-joists unless you located it over a beam or reinforced the i-joist from below. First off, the cantilever is free slung out side the house with no support underneath, other than the I-joists. this is why Chin_Lee suggested the supporting the out side edge of the cantilever. Also as I already said I-joist are not engineered for point loading , squash blocks ( 2X10's) must be used beside I-joists between squash points ( bearing walls)

What do you suggest

Thanks
__________________
HAPPY REEF KEEPING !!______________________
Reply With Quote
  #6  
Old 10-23-2006, 04:30 AM
mr_alberta's Avatar
mr_alberta mr_alberta is offline
Member
 
Join Date: Apr 2003
Location: Edmonton, AB (University Area)
Posts: 2,506
mr_alberta is on a distinguished road
Default

Can you get the builder to double up the joists in that location? How much of a cantilever are we talking about?
__________________
32"x32"x20" Cube-ish tank
Reply With Quote
  #7  
Old 10-23-2006, 04:38 AM
Tarolisol's Avatar
Tarolisol Tarolisol is offline
Member
 
Join Date: Sep 2004
Location: calgary
Posts: 1,020
Tarolisol is on a distinguished road
Default

I have a rather heavy piano in my cantilever, as im sure many others have as well. And its been there for years, im sure it weighs as much as a tank.
__________________
Sean

Back in the good ole days
Reply With Quote
  #8  
Old 10-23-2006, 05:12 AM
Farrmanchu Farrmanchu is offline
Member
 
Join Date: Jun 2006
Location: Winnipeg
Posts: 210
Farrmanchu is on a distinguished road
Default

Check with Chemaster, I think his tank sits partially outside the foundation, and he had some beefing up done before putting the tank in.
Reply With Quote
  #9  
Old 10-23-2006, 07:08 AM
Dale's Avatar
Dale Dale is offline
Member
 
Join Date: Jun 2006
Location: Abbotsford, BC.
Posts: 189
Dale is on a distinguished road
Default Go

I've had a 6', 140G. tank sitting in my cantilever for a year now without a problem. Consider that it will weigh in at just over 1000lb's - or the weight of five big guys. Will the cantilever collapse if five big guys stand in it? As suggested the tank sits on a load bearing wall and if your tank is say, 20" wide only 16" actually protrude beyond the wall itself. That 16" is cantilevered which means it is supported by the load bearing wall.
here's a pic:

________
Kawasaki KR350

Last edited by Dale; 01-21-2011 at 01:31 PM.
Reply With Quote
  #10  
Old 10-24-2006, 12:02 AM
Josh24's Avatar
Josh24 Josh24 is offline
Member
 
Join Date: Jul 2003
Location: Calgary
Posts: 42
Josh24 is on a distinguished road
Default

Thanks Dale I doubt my tank would exceed 140 gallons.
Have you noticed an increase in bounce in your floors?
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 11:32 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.