![]() |
|
#1
|
|||||
|
|||||
![]() Looks like you could easily put a check valve on the return to solve your sump overflow issue.
|
#2
|
||||
|
||||
![]() The water level in the overflow box looks too high, a lower standpipe might help. It's hard to troubleshoot these type of problems from pics. Maybe wider slots in the overflow. Anyways, you want to bring the tank water level down somehow, and have as much room as possible in the sump. Check valves can fail, then you still have the worry of an overflow. Lockline going from the bulkhead to within an inch of the surface would do the trick too.
|
#3
|
|||||
|
|||||
![]() I had no idea Mike customizes the tanks.. I assumed it came from the factory like this. I will definitely need to take the standpipe out and cut it down I guess. I supposed I wouldn't have to glue the coupler on when I join it back together would I? If I left it unglued, then I have the ability to adjust the length at any time.
I had thought about putting a check valve inline with the return but have heard that they do fail and so I'd rather fix it at the output. Would locline seal enough to prevent water from seeping back down the return line? Or would I have to put solid PVC up to the surface and then run locline from there? I have been only turning on the return pump when I get home from work in the evenings because I'm scared something is going to go wrong. I'm glad I put that ball valve in there.
__________________
Jeremy |
#4
|
|||||
|
|||||
![]() I would give Mike a call. The overflow teeth do not look like what usually comes out of Mike store. Maybe he could redo the overflow box and bring the return up over the overflow
J |
#5
|
||||
|
||||
![]() Put a tee on your return with a ball valve. The straight part of the tee goes to the tank the other part of the tee goes back to the sump. Put the valve on the pipe going to the sump. This way you can control the volume of water going to the display tank without restricting your pump.
|
#6
|
|||||
|
|||||
![]() You could raise the level of the return by adding a couple of elbows after the bulkhead. I concur with Hawks suggestion for reducing the flow to the tank. Lowering the standpipe will likely not solve anything as the flow is simply exceding its capacity. You would have to have a larger standpipe if you want to open up the flow more.
__________________
I retired and got a fixed income but it's broke. Ed _______________________________________ 50 gallon FOWLR, 10 gallon sump. 130 gallon reef, 20 gallon sump, 10 gallon refugium. 10 gallon quarantine. 60 gallon winter tank for pond fish. 300 gallon pond with waterfall. |
#7
|
|||||
|
|||||
![]() Thanks again for the replies. I don't think I am going to go and redo the overflow box now... I went through enough hell getting the tank set up at our current house (floor was very uneven, rubbermaid containing livestock while tank was being leveled started leaking all over the carpet etc).
I am going go try lowering the standpipe first to see what that does. When I had the pump opened right up, I could look down the top of the standpipe and it sure looked like there was plenty of room for that much water going down there. I think the problem is that more room is needed above the opening to the standpipe in order for that much water to drain due to surface tension probably? I will also take your suggestions and put a couple of 45's or 90's on the output of that bulkhead to bring the line up to the surface before attaching any locline. We'll see how that goes I guess. Thanks again guys.
__________________
Jeremy |