Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > DIY

Reply
 
Thread Tools Display Modes
  #1  
Old 04-25-2006, 03:20 AM
Johnny Reefer's Avatar
Johnny Reefer Johnny Reefer is offline
Member
 
Join Date: May 2005
Location: Victoria, B.C.
Posts: 1,192
Johnny Reefer is on a distinguished road
Send a message via MSN to Johnny Reefer
Default

Quote:
Originally Posted by TheReefGeek
Im talking about an auto top off with an RODI unit, which a single abs float valve is not going to do. If you think it will, please explain in DETAIL.
Not sure what "abs" stands for, but I believe this might be one?
http://www.hagen.com/canada/english/...03018420010101

If I'm not mistaken, an RO/DI unit can be hooked up to it. Hard to see in the picture but the tubing connects to the small adapter piece seen in the package on the left hand side. Just above that tapered piece.

When I get my crap together and move and do some major upgrading at the same time, I plan on running an RO/DI unit straight to float valves (multiple tanks) exactly like this one.

Sorry Ruth. Had to get that in.

Cheers,
__________________
Mark.
Reply With Quote
  #2  
Old 04-25-2006, 04:11 AM
TheReefGeek's Avatar
TheReefGeek TheReefGeek is offline
Member
 
Join Date: Jan 2006
Location: Edmonton, Alberta
Posts: 1,503
TheReefGeek is on a distinguished road
Default

Can't tell much from the picture, but I don't think that will control your RODI unit.

If you want to run your RODI unit to float valves, you will have to rely on pressure in the line (created when the float valve closes) to trigger a diaphram in a hyraulic valve plumbed right into your RODI unit. It is actual the pressure difference on the two sides of the diaphram that triggers it to shut off water to the RODI, thus cutting off waste water production as well. BUT, if your line between the RODI and the float valve(s) is too long, you will have to install pressure bladders (check out spectrapure systems for an example of these) to create enough pressure to trigger the diaphram to flip.

The other way is to control it electronically with float valves. Very possible but I have had too many fail open to trust them anymore myself.
__________________
Rory

Reply With Quote
  #3  
Old 04-25-2006, 06:50 AM
Willow's Avatar
Willow Willow is offline
Member
 
Join Date: Jan 2005
Location: Richmond, BC
Posts: 1,485
Willow is on a distinguished road
Send a message via MSN to Willow Send a message via Yahoo to Willow
Default

you know the aquasafe units have a built in auto shut off unit. i still wouldnt hook it directly to my tank but you could.
__________________
Given sufficient thrust pigs will fly just fine.

90 Gallon LPS tank - Challice, Acans, Favia, Diplo and Zoos
125 Gallon SPS Coming Soon!
Reply With Quote
  #4  
Old 04-25-2006, 03:28 PM
Delphinus's Avatar
Delphinus Delphinus is offline
Member
 
Join Date: Dec 2001
Location: Calgary
Posts: 12,896
Delphinus has a spectacular aura aboutDelphinus has a spectacular aura aboutDelphinus has a spectacular aura about
Send a message via MSN to Delphinus
Default

It's not necessarily a good idea to hook up the RO/DI to a tank anyhow, even if you have the solenoid shutoff control. The problem is that the evaporation rate is 24/7, so you would be constantly cycling the RO/DI on and off for short bursts. And actually, a higher GPD rating of the membrane compounds this, as you'll have it on for only a few seconds at a time before the level is maintained again. This is murder on a RO membrane and will contribute to early failure of the membrane.

As far as I'm concerned, the auto shutoff feature of a RO/DI unit should be used to avoid spillage when filling your reservoir. I.e. if it takes 10 hours to fill your reservoir you can just turn it on and forget about it, not have to worry about remember 10.5 hours later that you now have an overflowing reservoir.

You could probably make it a little better by expanding your deadband by creative use of float switches but even then .. it's still the same problem of repeated on/off cycles. I.e., say 40gpd replacement water per week, your membrane will last you much longer if you do one production run of 40g instead of 100 production runs of .4g.

Thus my recommendation is float valves on your sump fed by a reservoir, RO/DI only to fill the reservoir using a float valve on the reservoir and the auto shutoff kit on the RO/DI as a luxury item to afford you peace of mind when manually filling that reservoir as needed.

PS. My $0.02 as far as float valves failing .. generally speaking this is a very rare occurence if set up properly and maintained regularly with diligence. Also the likelihood of failing is more in the nature of a clog, rather than failing stuck open. So if you find your float valve clogged, you just clean it and away you go.
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!
Reply With Quote
  #5  
Old 05-04-2006, 03:35 AM
albert_dao albert_dao is offline
Good Guy Albert
 
Join Date: Jun 2004
Location: Richmond
Posts: 3,035
albert_dao will become famous soon enough
Send a message via MSN to albert_dao
Default

Quote:
Originally Posted by Delphinus
OH LOOK AT ME, I'M TONY AND I HAVE 5700 POSTS.

...


....


Well Tony, I don't know what to say to that.
__________________
This and that.
Reply With Quote
  #6  
Old 05-04-2006, 04:03 AM
Delphinus's Avatar
Delphinus Delphinus is offline
Member
 
Join Date: Dec 2001
Location: Calgary
Posts: 12,896
Delphinus has a spectacular aura aboutDelphinus has a spectacular aura aboutDelphinus has a spectacular aura about
Send a message via MSN to Delphinus
Default

Uh .. Ok, I'm not really sure how to take that. Um .. haha?
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!

Last edited by Delphinus; 05-04-2006 at 05:12 AM.
Reply With Quote
  #7  
Old 05-04-2006, 09:29 AM
albert_dao albert_dao is offline
Good Guy Albert
 
Join Date: Jun 2004
Location: Richmond
Posts: 3,035
albert_dao will become famous soon enough
Send a message via MSN to albert_dao
Default

Quote:
Originally Posted by Delphinus
Uh .. Ok, I'm not really sure how to take that. Um .. haha?

Just bangin on ya Tony, haha :P
__________________
This and that.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 09:45 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.