![]() |
|
#1
|
|||||
|
|||||
![]() And that is not an auto top off unless you run the RODI into your tank not a garbage can.
When your distance from RODI unit to destination is too great, there is not enough pressure build up in the line to trigger the hydraulic valve (which you didn't mention, and if you don't have, then your waste water production NEVER stops!) to shut down the RODI unit. This is why drinking water systems use pressure bladders to build up the required pressure. Also relying on a single float valve builds in no redundancy for when it clogs and fails open. |
#2
|
|||||
|
|||||
![]() And in terms of "over-engineering" I think that a sprinkler solenoid and timer is just as easy to install than a float valve, if not easier because you dont have to drill anything.
Sorry this sounded so harsh, but when it comes to auto-top off and the potential for flooding, I take giving accurate information very seriously because it is the kind of thing that gets people out of the hobby after a flood that kills off your tank. Last edited by TheReefGeek; 04-24-2006 at 07:13 PM. |
#3
|
|||||
|
|||||
![]() Quote:
?? dude what are you talking about? abs float valves are gravity fed, no hydraulics, no pressure and you don't need a backup system. it floats, when it needs water it opens a seal and water flows thru when it gets up to level it shuts off. there is littlerly no safer or user friendly fail safe system better that an abs float valve. and you defiantly don't have to drill anything. i think you need to go back to the drawing board on your theories of how float valves work.
__________________
Given sufficient thrust pigs will fly just fine. 90 Gallon LPS tank - Challice, Acans, Favia, Diplo and Zoos 125 Gallon SPS Coming Soon! Last edited by Willow; 04-24-2006 at 08:22 PM. |
#4
|
|||||
|
|||||
![]() Quote:
Im talking about an auto top off with an RODI unit, which a single abs float valve is not going to do. If you think it will, please explain in DETAIL. You would need to install a hydraulic valve that triggers when there is pressure build-up in the line, and the valve closes the waste water production for you. Otherwise, when your abs float valve closes, your RODI unit just keeps on pumping out waste water. Float valves can fail open, if anything clogs them from closing properly, then water just keep on flowing! |
#5
|
|||||
|
|||||
![]() I don't care how brilliant the design I would never attach a RO/DI unit directly to a top off. I have a 100GPD RO/DI and would not want a failure in that to flood my system.
Having a holding tank that supplies your AUTO-TOP-OFF is still and AUTO-TOP-OFF. J |
#6
|
|||||
|
|||||
![]() Yep, it absolutely is, never said anything different. But I find that you then need two auto-top offs. One to control your RODI to a reservoire, then one from your reservoire to your sump/display.
|
#7
|
|||||
|
|||||
![]() Anyhow, shouldn't be filling this thread with an auto-top off discussion.
|
#8
|
|||||
|
|||||
![]() Quote:
Quote:
__________________
Given sufficient thrust pigs will fly just fine. 90 Gallon LPS tank - Challice, Acans, Favia, Diplo and Zoos 125 Gallon SPS Coming Soon! |
#9
|
|||||
|
|||||
![]() A float valve from a humidifier to your R/O unit should suffice. As a failsafe, you can use a float switch hooked up to a solenoid that cuts off the water supply to your R/O unit if the water level in your sump gets too high in conjunction with the float valve. If you are really worried, you can set up a couple of switches in case 1 should fail (if everything fails, you're just unlucky!
![]()
__________________
32"x32"x20" Cube-ish tank |
#10
|
|||||
|
|||||
![]() Quote:
http://www.hagen.com/canada/english/...03018420010101 If I'm not mistaken, an RO/DI unit can be hooked up to it. Hard to see in the picture but the tubing connects to the small adapter piece seen in the package on the left hand side. Just above that tapered piece. When I get my crap together and move and do some major upgrading at the same time, I plan on running an RO/DI unit straight to float valves (multiple tanks) exactly like this one. Sorry Ruth. Had to get that in. Cheers ![]()
__________________
Mark. |