Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #1  
Old 02-13-2006, 03:43 AM
Johnny Reefer's Avatar
Johnny Reefer Johnny Reefer is offline
Member
 
Join Date: May 2005
Location: Victoria, B.C.
Posts: 1,192
Johnny Reefer is on a distinguished road
Send a message via MSN to Johnny Reefer
Default

IMHO I think you should go back to the way you had it 3 months ago until you can invest in and set up a drilled tank. Don't even bother with a siphon overflow.
I learned my lesson with siphon overflow boxes 9 months ago.
Didn't have a flood but I could see one comin'. Not worth the risk.
Got a drilled tank now and it is waaaaaaaaayyyyyy better.
Maybe not the answer your lookin' for, but that's my humble opinion on it.

Cheers,
__________________
Mark.
Reply With Quote
  #2  
Old 02-13-2006, 06:26 AM
TheReefGeek's Avatar
TheReefGeek TheReefGeek is offline
Member
 
Join Date: Jan 2006
Location: Edmonton, Alberta
Posts: 1,503
TheReefGeek is on a distinguished road
Default

Is this overflow a u-tube design? Is your SEIO 820 for sucking out air in the top of the u-tube?

If it is a u-tube, are you priming it? Are both ends of the u-tube submerged in water when power goes out? My guess is your u-tube has broken siphon, you need to prime it, and make sure both ends stay submerged when you power goes out, this is easy to test.

Johnny, can you explain why your overflow almost flooded? I just dont want to scare people away from them without knowing why. External overflow boxes can be setup completely flood-proof IME, but most people do not take the necessary precautions, the devices are as safe as they are setup and maintained.
__________________
Rory

Reply With Quote
  #3  
Old 02-13-2006, 02:46 PM
wetcoast's Avatar
wetcoast wetcoast is offline
Member
 
Join Date: Dec 2005
Location: surrey, bc
Posts: 113
wetcoast is on a distinguished road
Default

The overflow is not a Utube design - it is more like a "Calfo" style or "Weir" style with various baffles inside of it. It has worked flawlessly for 3 months without any issue - which is why there is a big concern with me..

Unfortunately just going back to the way it was is not an option - I woke up this morning to find my fish gasping at the water for oxygen - due to the lack of movement from just the two powerheads. I have thrown an airstone and a couple more powerheads towards the surface for now until I can get home from work. I will have to find a way to get the skimmer to work if this is going to be more than a couple days - either way this is frustrating!

The SEIO powerhead is constantly connected to the air nipple sucking from the top which is how I get the siphon to start in the first place..

Any other thoughts would be appreciated..
Reply With Quote
  #4  
Old 02-13-2006, 03:39 PM
TheReefGeek's Avatar
TheReefGeek TheReefGeek is offline
Member
 
Join Date: Jan 2006
Location: Edmonton, Alberta
Posts: 1,503
TheReefGeek is on a distinguished road
Default

Does it look like this? Is the siphon breaking? Maybe you have a slow leak in it, enough that when the power goes out it leaks and loses siphon?

__________________
Rory

Reply With Quote
  #5  
Old 02-13-2006, 03:46 PM
wetcoast's Avatar
wetcoast wetcoast is offline
Member
 
Join Date: Dec 2005
Location: surrey, bc
Posts: 113
wetcoast is on a distinguished road
Default

Yes looks very similar to that.

I have taken the box right off and attempted to start the siphon all over again with no such luck. It doesn't LOOK like there are any leaks or holes in the acrylic and I can hear a sucking sound when the hose is attached to the top nipple of the box to suck air out.

I think I may be able to get a utube type box today for testing and will see how it goes - but the fact of the matter is - this doesn't make any sense at all - It wont even start sucking from the "inside of tank" part of the box

.. and everything was going so good lately..
Reply With Quote
  #6  
Old 02-13-2006, 03:51 PM
TheReefGeek's Avatar
TheReefGeek TheReefGeek is offline
Member
 
Join Date: Jan 2006
Location: Edmonton, Alberta
Posts: 1,503
TheReefGeek is on a distinguished road
Default

Maybe your Seio pump is broken?

Try taking a line of 1/4" airline tubing, and fishing it into the middle, and sucking air out yourself to prime the overflow. This is how I started my u-tube overflow.
__________________
Rory

Reply With Quote
  #7  
Old 02-14-2006, 02:14 AM
Johnny Reefer's Avatar
Johnny Reefer Johnny Reefer is offline
Member
 
Join Date: May 2005
Location: Victoria, B.C.
Posts: 1,192
Johnny Reefer is on a distinguished road
Send a message via MSN to Johnny Reefer
Default

Quote:
Originally Posted by TheReefGeek
Johnny, can you explain why your overflow almost flooded?
It didn't almost flood. I said I could see one comin'...meaning if I kept with the siphon overflows I envisioned a flood in the future.
Started with two overflow boxes, one U-tube in each. Did a test to see what would happen if one U-tube lost siphon. Test failed. The one siphon left couldn't keep up with the return. So, I doubled up the U-tubes. Two in each box. But then there was too much distribution and one U-tube would lose siphon over a long period of time, leaving only three doing the job. One day I noticed salt creep on the plumbing to the sump. So I shut the pumping down to silicone the plumbing joints. My sump slooooooowly continued to fill with water. Turned out water was being siphoned out into the sump through the powerhead's airline tubings. Oh ya? So how do I stop this? Check valves in the airline tubing. So I went out and bought a bunch of check valves. But I never installed them. I decided @*^%$# this. Shut the sump down, went back to a canister filter and pressed on as before until I could afford a drilled tank.
I should qualify this by saying that part of my decision was the fact that I worked away from home for long periods around that time. But still, wether one is working 500 miles away or 5 blocks away, a flood is a flood. You just find out about it sooner if you are 5 blocks away. JMHO.

Cheers,
__________________
Mark.
Reply With Quote
  #8  
Old 02-14-2006, 03:40 AM
wetcoast's Avatar
wetcoast wetcoast is offline
Member
 
Join Date: Dec 2005
Location: surrey, bc
Posts: 113
wetcoast is on a distinguished road
Default

So after my boss sent me home early today to take care of the mess I was about to deal with - I came in and noticed why my fish were gasping for air this morning, I only had one powerhead going all night due to my mucking around to see if the powerheads were broken (to answer the above question). The airstone and extra powerheads I threw in before going to work helped alot, all livestock was alive.

I decided to give it a whirl again today and everything worked as planned without issues! I just don't understand what the heck is going on here. Mind you - I don't trust it. Looking for a 65gallon tank to drill and then will sell this one.

The saga continues.
Reply With Quote
  #9  
Old 02-14-2006, 05:43 AM
TheReefGeek's Avatar
TheReefGeek TheReefGeek is offline
Member
 
Join Date: Jan 2006
Location: Edmonton, Alberta
Posts: 1,503
TheReefGeek is on a distinguished road
Default

If a u-tube loses siphon, it just means that your pump in your return section of the sump will continue pumping water into your display.

This is not good, but not that bad either, as long as you have measured the additional capacity of your tank, and not built your return section larger than that.

In this case, all that will happen is your pump will run dry, but no flood. To solve this, use a float switch set to turn the pump off if the water level drops too low. Add a second as back-up, and there should be no way to flood.
__________________
Rory

Reply With Quote
  #10  
Old 02-16-2006, 02:31 AM
Johnny Reefer's Avatar
Johnny Reefer Johnny Reefer is offline
Member
 
Join Date: May 2005
Location: Victoria, B.C.
Posts: 1,192
Johnny Reefer is on a distinguished road
Send a message via MSN to Johnny Reefer
Default

Quote:
Originally Posted by TheReefGeek
To solve this, use a float switch set to turn the pump off if the water level drops too low. Add a second as back-up, and there should be no way to flood.
I just think that the more gizmos and gadgets one has, the more things they have that could malfunction and go wrong. The external system I had, I decided, was getting too complicated with to many "parts" and thus an increased potential for one of those parts to malfunction. The simpler, the better. IMHO.

For the cost of the external box(es), the powerheads, the check valves, the switch, etc. ...why not just pay a little extra and get a drilled tank and buy some peace of mind at the same time?

BTW...I disagree with there being such a thing as a flood proof external siphon overflow system. Sorry.

Cheers,
__________________
Mark.
Reply With Quote
Reply


Posting Rules
You may not post new threads