#1
|
|||||
|
|||||
![]() You may want to do a quick google search on the durso standpipe, stockman standpipe or hoffer gurgle buster. Basically fancy plumbing on the intake the reduce the noise.
My personal preference, is if there are 2 holes/bulkheads, put a simple stand pipe in one (emergency overflow) then add a ball valve to the second, reducing the flow so that the water level stays steady (and completely covering) the drain - no noise at all. |
#2
|
||||
|
||||
![]() here's some links u may want to try
http://home.nc.rr.com/stockmanreef/interest.htm http://www.rl180reef.com/pages/stand...pipe_frame.htm Last edited by tbone; 01-03-2006 at 03:46 AM. |
#3
|
||||
|
||||
![]() Just one hole and it's in the side. The pressure line comes over the top to give syphon break. I'll check the links and the suggestions though. Thanks
__________________
This all started with a ten gallon and two clowns. |
#4
|
||||
|
||||
![]() Aqua silencer is a great thing. I have built something similar with a standing piece of pipe with abou six hundred hand drilled holes
![]()
__________________
This all started with a ten gallon and two clowns. |