Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Tank Journal

Reply
 
Thread Tools Display Modes
  #1  
Old 08-20-2005, 06:08 AM
Charlie_Tuna's Avatar
Charlie_Tuna Charlie_Tuna is offline
Member
 
Join Date: May 2005
Location: Blackfalds, Canada
Posts: 25
Charlie_Tuna is on a distinguished road
Default Drilled Tank Question

I am purchasing an acrylic 120 gallon tank, pre-drilled with overflow.

The tank has an additional hole drilled in the bottom for a direct return line.

If I choose to use this return method, should I not be paranoid in terms of power outtage? I have heard that PVC check valves get dirty quickly and can be unreliable.

Would I be better off finding some way to cap this hole, and run my return line up and over, so that I could drill a hole in the return line just under the water level? Is this reliable?

Also, any suggestions as to sump size?

Your help is greatly appreciated!

Charlie_Tuna
Reply With Quote
  #2  
Old 08-20-2005, 09:47 AM
BT05 BT05 is offline
Member
 
Join Date: Jun 2005
Posts: 40
BT05 is on a distinguished road
Default

Not sure if I'm reading this correctly but are you saying that the additional hole is drilled in the bottom outside of the overflow? Or do you have 2 holes drilled inside the bottom of overflow box; 1 for drainage, 1 for return?

In either case, you should have your main return line plumbing go above the water level, tee it off, then place the outlets down about an inch or two below the water line. If you just leave it as is and return water directly without *any* plumbing above the bulkhead (bottom of the glass), the entire tank will drain in a power outage. I wouldn't rely on a check valve regardless of the setup.

You can drill a hole in the return line but it needs to be fairly large in order to be effective and it can also get clogged with algae, snails, etc. once the siphon starts. One way to guard against power outages is to pick an appropriately sized sump that can hold the excess water siphoned from the tank when power goes out. This means that you keep the water line of the sump only halfway when the tank is in use. For your tank, maybe a 50+ gallon sump would do depending on how far down the return outlets go below the water level. Gives you a ~25 gallon room for error.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 11:42 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.