So good ole level control etc etc

Lets start with the basics.

ATO.

There are different ways of doing this

Direct from the RO unit (my choice)
From storage container (most popular)
From one of the above controlled by a salinity probe instead of level sensor (advance topic - later)

So which ever you choose of the first two the only thing that changes in the set up is what you plug into the assigned power bar socket, whether it be a water solenoid of water pump. In my case water solenoid.

So first thing we must do is set a float or optical level sensor up in the sump to the desired (controlled) level point.

Here is mine.



Set up the assembly and loose fit to the sump so it can be adjusted, now go to the profilux front screen and go to level - diagnostic - level 1, adjust the sensor until it just turns off, you now have your level set at where you wish the water to always be maintained at.

So back to the software.

Go to the level control screen



By now you should have plugged in your sensor to the back of the profilux and not by mistake plugged it into the temperature port instead :celeb1:

Double click on Level 1 in the settings tab at the top and up pops -



In this box you can set all sorts of treats, the first important thing to set is the function, in this case ATO, the next most important is Max on time, this is your safety net, lets say heavens forbid you forgot to clean your ATO sensor and it stuck on, you are in Cuba and downing a lovely cool local brew while your ATO goes AWOL and floods the Granny apartment below! To avoid such minor issues here you set the maximum time you wish the sensor to be in an active state. So in my case 5 minutes is, well probably to long and needs to adjust that down to 30 seconds, thats a good target. So now you have fail safe ATO

next in the same screen you need to set up the reaction time, no this is not the time you have to get back from Cuba to sort out the mess in the apartment below, but the amount of time the sensor is active before the controlled socket is switched, this is ideal for tanks with turbulance or other things that can make the sensor switch on and off periodically. I have mine set to 5 secs, which is just right.

So thats the ATO sensor set up, what about the socket?

You have now chosen a socket to control your pump or solenoid. Just as before go to socket function and click edit the chosen socket. Set this to water 1.

Waheyy, you now have fail safe fully set up ATO