Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > Vendor Forums > Oceanic Corals > Everything L.E.D.

Reply
 
Thread Tools Display Modes
  #1  
Old 04-20-2010, 03:46 PM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

Quote:
Originally Posted by StirCrazy View Post
wohwoh man, I never said they wern't related only not the only factor. the simmple fact is if the big blue spike shifts to the left, PAR will drip off as it shifts compound this with a decrease in intensity and it will be compounded.

you can not gage PAR out put with LUX, two totaly diferant and unrelated measurments. you are in one case measuring the amount of the emitted light with in a specific wave length, in the other you are measuring the amount of visiable light that falls on a given area. kind of a mass vs PSI but of different componants. Like I said in the previous post, no two MH or T5, ect age identicaly. this is due to various factors, including gas concentrations/types inside and so on. LED eliminates this by using a solid state chip encapsulated with no air/gas/ect surounding the chip, but they do have a problem as mentioned... heat. if they are allowed to warm up they will go through a reduction in PPF, which rises again once cooled. this can be as much as a 30% reduction in as little as 1/2 an hour with out any cooling and no drop in intensity. so using a heat sink and fans properly is a twofold benifit.. maintains the PPF output and the life on the LED. I think you would need the fans personaly, other wise the fixtures would be huge inorder to give each LED enough heatsink to make passive cooling possible. by having fans and preperly using them you will be able to produce lighter, more sleak fixtures. for what it is worth I had 4 computer fans running over my sump for 8 years starting and stopping 4 times a day. although they were coated with salt spray they still worked..

Steve
Agreed that you can't measure PAR from lux directly, obviously the PAR of a bulb depends on the spectrum distribution. However that was never my point. I'm purely talking about bulb wear and the simple fact is a decrease in PAR over time is the result in an overall decrease in intensity which could be measured by LUX. For example mass and psi are separate measurements but if you have a mass over a given area and the area and gravitation force remains constant then a decrease in PSI means a decrease in mass.

Your "big blue spike" does not shift, or move to the left or right, it simply decreases in intensity and the overall CCT shifts to a lower K rating. Depending on the bulb you can also see an increase in other areas of the spectrum like red and green which is why some bulbs will actually increase in PAR overtime or stay relatively constant. In order for PAR to decrease the overall intensity of the bulb must decrease.

As for fans, they are not needed, there are already plenty of LED lights for other applications which use high powered LEDs with properly designed heat sinks and no fans. It's a simple mater of cutting costs and the temperature gradient and heat transfer rate of LEDs is high and low enough respectively to eliminate the need for convective cooling. Computer components like CPUs run much hotter, their heat flux is way higher than an LED and require convective cooling. Computers are also built as cheap as possible, it's a huge commodity market.
Reply With Quote
  #2  
Old 04-19-2010, 01:51 PM
StirCrazy's Avatar
StirCrazy StirCrazy is offline
Member
 
Join Date: Oct 2001
Location: Kamloops, BC
Posts: 7,872
StirCrazy is on a distinguished road
Default

Quote:
Originally Posted by sphelps View Post
Perhaps the warranty isn't as big of an issue. Most other fixtures and equipment we use is usually limited at 1 year as well. The difference with these LED fixtures is they are new and marketed as something that will last 10 years and save you money in the long run. Manufacturers could back up these claims by offering better warranty and with a higher end fixture I would expect it to be that way but perhaps such a fixture doesn't exist yet. I wouldn't expect the warranty to cover every component but if I look at my RD pump it was marketed as an efficient quality pump designed to last longer and therefore actually save you money in the long run. It comes with a lifetime warranty on the bearings. I've had bearings fail on other pumps and while it's not the only component that can fail it still says the manufacturer is standing behind there claims and product.
ya warenty is a tough one.. I can build you a light fixture that is bullit proof, but I can guarentee the ballasts or bulbs will last more that what the warentee I get when I buy them.. now pumps and berrings is a different story, there is no reason any manufacture can't offer life time warenty on berrings as you'll find that is any simular sized pump designed to do the same thing the berrings will be very simular if not the same. I have been rebuilding pumps as part of my former job for over 20 years and it was very very rare I came across a berring problem. most of the time the pump wore out befor the berring did. but we did change berrings on some just becaue they are very cheep and we were rebuilding the rest of the pump, but I did save the old berrings for emergency spares..

Steve
__________________
*everything said above is just my opinion, and may or may not reflect the views of this BBS, its Operators, and its Members. If cornered on any “opinion” I post I will totally deny having ever said this in a Court of Law…Unless I am the right one*

Some strive to be perfect.... I just strive.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 11:46 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.