![]() |
|
#1
|
|||||
|
|||||
![]() Quote:
your Hi quality T5 set up you showed there, is there any distance referances? and whats the point of taking readings int he air 1/2 way between the reflector and the water? so just under the surface it looks like he has a 575 average in the well lit area. at the bottom about 280ish. the hot spot is a little higher than the numbers but the other areas are lower. (I never realized the hot spot on T5s would be that pronounced) at any rate His number were very comparable with your high end T5 with new bulbs. although we would need measurments of all the reading positions to be sure. so what happens if he adds more LEDs.. nothing, bt if he adds more LEDs to reduce his spacing then adds 40 degree optics his numbers should jump by about 50% from what I have been seeing. if he adds more and then goes 20% optics.. problem is the spacing is so tight on 20% or lower optics it would only be a reasonable cost on a 20 gal tank or less, but man would you pack some punch. I know there are some people trying the the newer bulbs that have about 3 times the output as the ones Ron is using but they don't make that strength in a Royal blue yet so it is only good for the white and they are finding it is to powerfull for any other lighting they try to give it a blue look as it just washes it out. now if you like the icewhite look to your tank, which I tend to.... they might be a awsome bulb to try. I am actualy going to buy a handfull of LEDs and build a tiny cylinder that is about 24" tall but small enough aroundI can lighting it with 2 or 3 LEDs so I can try some different combos on my Ardunio and see what kind of color blending, lenses and PAR values I can get a different depths. just have to clean my shop out first.. which at the way I am goiong should be another 6 months ![]() Steve
__________________
![]() Some strive to be perfect.... I just strive. |
#2
|
|||||
|
|||||
![]() Quote:
The tank pictured above is 5' with a 4' fixture over it. The tank is 60 x 30 x 24. The fixture is roughly 6-7" above the water's surface. The edges of the tank are dim because the fixture does not extend to the edge and because the first 3" or more of a T5 lamp produce significantly less light. Within the 3.5" feet centered below the fixture the PAR is pretty consistent (biased on one side because that's where the fans are).
__________________
SPS Dedicated 24x24x20 Trimless Tank | 20 g Sump | Bubbble King Mini 160 Protein Skimmer w/ Avast Swabbie | NP Biopellets in TLF Phosban Reactor | ATI Sunpower 6 x 24W T5HO Fixture | EcoTech Vortech MP20 | Modified Tunze Nanostream 6025 | Eheim 1260 Return Pump | GHL Profilux Standalone Doser dosing B-Ionic | Steel Frame Epoxy Coated Stand with Maple Panels embedded with Neodymium Magnets "Mens sana in corpore sano" |
#3
|
|||||
|
|||||
![]() And Ron, I apologize for derailing your build thread.
__________________
SPS Dedicated 24x24x20 Trimless Tank | 20 g Sump | Bubbble King Mini 160 Protein Skimmer w/ Avast Swabbie | NP Biopellets in TLF Phosban Reactor | ATI Sunpower 6 x 24W T5HO Fixture | EcoTech Vortech MP20 | Modified Tunze Nanostream 6025 | Eheim 1260 Return Pump | GHL Profilux Standalone Doser dosing B-Ionic | Steel Frame Epoxy Coated Stand with Maple Panels embedded with Neodymium Magnets "Mens sana in corpore sano" |
#4
|
||||
|
||||
![]() I have a 48" 10 bulb ATI Powermodule on my home tank, the 48" Aqua Illumination module I have seen is brighter than my Powermodule. This of course is just my observation.
On a second note, Ron, you are more than welcome to come over and pull some numbers off my tank. Also, it would be nice to see all of this back and forth discussion on the comparatives between LED and conventional lighting moved to a new thread for this purpose. I was actually just enjoying Ron's build thread as it was. Ian |
#5
|
|||||
|
|||||
![]() Quote:
so I can safly say that a good LED set up such as Ron's will blow any T5 out of the watter, most 150 watt setups, and some of the 250 watt setups. if he would have gone a little tighter spacing which allowed for 40 degree optics with out spotlighting I can say you would be hard to find a MH system that would be a higher output, and it would be pointless to try as at that output level would it realy matter? Is this because you spent to much on your T5 set up and are haveing buyers regrets Andrew? ![]() ![]() Steve
__________________
![]() Some strive to be perfect.... I just strive. |
#6
|
|||||
|
|||||
![]() Quote:
Quote:
Quote:
And this isn't an issue of T5s versus the world. I generally comment on comparison threads when garage "scientists" take it upon themselves to make comparisons as if they're conducting controlled experiments (not that Ron did this or is a "garage scientist" but I didn't want others to try to make comparisons as if the two fixtures were representative examples). The comparison to T5 lighting in this thread is not representative. Had Ron compared his DIY LED fixture to a Coralife MH fixture with a one year old 20,000K MH bulb I would have made similar comments about unfair comparisons. Likewise, I think Sanjay's comparison of the older model AI module to a crappy MH setup with 20,000K lamp is hardly a fair and representative comparison. I love that you guys are helping develop LED fixtures and ideas for those of us who don't want to go the DIY route. You'll help push manufacturers to make better hobbyist fixtures. And I love that you guys are so enthusiastic about what you're doing. What my concern is, is that some people are getting caught up in the enthusiasm (and blatant marketing hype) and losing site of objectivity. Historically, the same thing happens with new lighting technology coming to the hobby. Reports about T5 longevity and PAR were completely off base for several years until real hard data started to be compiled. The same thing is happening with LEDs to some extent right now. Fortunately, LED lighting is still in it infancy (especially for use in our hobby) and is bound to improve and at the same time some controlled quasi-experimental data will start to emerge.
__________________
SPS Dedicated 24x24x20 Trimless Tank | 20 g Sump | Bubbble King Mini 160 Protein Skimmer w/ Avast Swabbie | NP Biopellets in TLF Phosban Reactor | ATI Sunpower 6 x 24W T5HO Fixture | EcoTech Vortech MP20 | Modified Tunze Nanostream 6025 | Eheim 1260 Return Pump | GHL Profilux Standalone Doser dosing B-Ionic | Steel Frame Epoxy Coated Stand with Maple Panels embedded with Neodymium Magnets "Mens sana in corpore sano" Last edited by Canadian; 04-13-2010 at 11:46 AM. |