are you planning on having a removable brace in the front. thats a long stretch with a lot of weight on just a 2x4.
__________________
If it is alive, I can most certainly kill it
Reply With Quote
  #2  
Old 04-28-2008, 05:58 PM
lastlight's Avatar
lastlight lastlight is offline
Gold Member
 
Join Date: Jan 2006
Location: Calgary
Posts: 6,997
lastlight has a spectacular aura aboutlastlight has a spectacular aura aboutlastlight has a spectacular aura about
Default

There is a 4 foot span across that opening. I'd really LIKE to put a vertical brace there...it just makes access difficult. Any other opinions on this? I might remove those two front braces and replace them with 1 inn the center and just deal with it. With an opening that's around 30" on each side I might be able to get a sump in there later I'm not sure. I wish I had the sump to test that.

What about this idea: I trim those front two supports shorter and insert another horizontal 2x4 on top of them spanning all the way across the front. So the front would realy be 2x8. Extending this idea to span that horizontal 2x4 across the actual corners would be nice but it's all glued and would be a real chore to rip apart...

Last edited by lastlight; 04-28-2008 at 06:04 PM.
Reply With Quote
  #3  
Old 04-28-2008, 06:01 PM
Delphinus's Avatar
Delphinus Delphinus is offline
Member
 
Join Date: Dec 2001
Location: Calgary
Posts: 12,896
Delphinus has a spectacular aura aboutDelphinus has a spectacular aura aboutDelphinus has a spectacular aura about
Send a message via MSN to Delphinus
Default

Cool stuff.

You could always double-up a 2x6 or 2x8 in behind the front beam maybe if you wanted to keep the area brace free.. I built the stand for my 280g using a 2x6 and a 2x8 doubled up to cover the span and when I had water in the tank I measured for any signs of deflection and could not find anything even after 2 months. I'm not a structural engineer though so I'm not sure if there's a better criteria.
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!
Reply With Quote
  #4  
Old 04-28-2008, 06:23 PM
lastlight's Avatar
lastlight lastlight is offline
Gold Member
 
Join Date: Jan 2006
Location: Calgary
Posts: 6,997
lastlight has a spectacular aura aboutlastlight has a spectacular aura aboutlastlight has a spectacular aura about
Default

At this point I think what I will do is simply make the center opening narrower. It's a little over 4 feet wide as it is but I'm not sure why i wanted to be able to push a 4 foot sump straight in. If i make that gap say 3 feet wide instead i can still slide the sump in and I don't think a 3 foot gap would be trouble at all.
Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 02:10 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.