Quote:
Originally Posted by SeaHorse_Fanatic View Post
Sidius,

If your ATO float switch failed in the "open" position, wouldn't it keep pumping water from the 29g and then the float switch in the ATO reservoir would refill, so you'd overflow your display/sump and drop the salinity? Also, if the float switch in the reservoir fails, you have freshwater all over your main floor. Neither scenario would please your wife or you.

I really like Reef Pilot's setup for failsafe, foolproof ATO system, cause having it timed (5 min every 6 hours) will really minimize any excessive RODI water dumpage, either into the display/sump or your floors.
Anthony
With my set up, both the solenoid (in the open position) and the float valve would have to fail before I could have an overflow. While theoretically possible, the mathematical probability of that is very, very minuscule. Especially, since the solenoid is spring loaded to close, and needs power to open. The much more likely failure is for the solenoid failing to open, which of course can't produce a flood.
__________________
Reef Pilot's Undersea Oasis: http://www.canreef.com/vbulletin/sho...d.php?t=102101
Frags FS: http://www.canreef.com/vbulletin/sho...d.php?t=115022
Solutions are easy. The real difficulty lies in discovering the problem.
Reply With Quote
  #2  
Old 10-07-2015, 09:23 PM
Reef Pilot's Avatar
Reef Pilot Reef Pilot is offline
Member
 
Join Date: Nov 2010
Location: Langley BC
Posts: 1,883
Reef Pilot is on a distinguished road
Default

Quote:
Originally Posted by Reef Pilot View Post
With my set up, both the solenoid (in the open position) and the float valve would have to fail before I could have an overflow. While theoretically possible, the mathematical probability of that is very, very minuscule. Especially, since the solenoid is spring loaded to close, and needs power to open. The much more likely failure is for the solenoid failing to open, which of course can't produce a flood.
And if you wanted to get really silly anal, you could have a double solenoid system, so if one does stay open the other one would still close the line. But then you would double the chance of a closed failure (much more probable).

These are not airliner systems where life (human that is) is at risk, so we have to be reasonable/practical with the cost of our risk mitigation.
__________________
Reef Pilot's Undersea Oasis: http://www.canreef.com/vbulletin/sho...d.php?t=102101
Frags FS: http://www.canreef.com/vbulletin/sho...d.php?t=115022
Solutions are easy. The real difficulty lies in discovering the problem.
Reply With Quote
  #3  
Old 10-07-2015, 09:41 PM
Aquattro's Avatar
Aquattro Aquattro is offline
Just a guy..
 
Join Date: Aug 2001
Location: Victoria, BC
Posts: 18,053
Aquattro is a jewel in the roughAquattro is a jewel in the roughAquattro is a jewel in the roughAquattro is a jewel in the rough
Default

Quote:
Originally Posted by Reef Pilot View Post
With my set up, both the solenoid (in the open position) and the float valve would have to fail before I could have an overflow. While theoretically possible, the mathematical probability of that is very, very minuscule. Especially, since the solenoid is spring loaded to close, and needs power to open. The much more likely failure is for the solenoid failing to open, which of course can't produce a flood.
I have the same setup. Has worked for 6 years without issue, other than solenoid failing closed about year 4, so simply replaced it.
__________________
Brad
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 02:24 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.