![]() I was looking to set up my RODI to the cold water line in the utility room, but discovered last night that the plumbing is completely done in ... not pvc, not copper, and not threaded vinyl... after some quick research I think it might be PEX. (can attach a picture tonight).
Has anyone any experience with attaching RODI to PEX plumbing? I assume I can't use the needle clamp thing that I wanted to.... Will I have to do it in line? Do I need special fittings? ![]() |
#2
|
|||||
|
|||||
![]() Do you think it would work to cut the line (if I can find somewhere to cut it), put in two PEX-PVC sharkbite push to connect fittings, and run a small PVC line between them and then clamp the RODI to the PVC?
|
#3
|
|||||
|
|||||
![]() |
#4
|
|||||
|
|||||
![]() Sharkbite connection should work, you just need to find an adapter to step down the size to the small diameter RODI tubing. I have copper, not PEX, but the photo below should give an idea of what's possible. I found a push type step down fitting at Can Tire. I'd say most stores dealing in plumbing fittings should have something similar.
You definitely want to include a shut off valve so that the RODI isn't under constant pressure. EDIT: Was responding while you posted the last photo of the metal fitting, looks like that should work just great.
__________________
Mike 77g sumpless SW DIY 10 watt multi-chip LED build ![]() Last edited by mike31154; 09-03-2015 at 03:10 PM. |
#5
|
|||||
|
|||||
![]() What I've done before is cut the Pex, install a Pex suitable tee, reconnect it. On the end of the tee use this fitting (buy a good quality one, not a cheap one):
![]() Or, if you can find it, use this one: ![]() |
#6
|
|||||
|
|||||
![]() There is no point introducing pvc into the supply line.
I would: Tee off from your main line with PEX crimp fittings Run a branch over to the RO unit. Add a ball valve where convenient to operate. Then step it down to a 1/4" quick connect to go to the RO unit. This ensures that the main lines in the house are using pex crimp rings. The quick connect is after a valve so that if any issues arise you can ensure that its off. Personally I don't trust the shark-bit fittings or any other quick connects. The slightest damage to the exterior of the pipe before installation or the o-rings during and you have potential for failure.
__________________
Ross 9 Gallon Nano, Modular LED Lights 14 Gallon BioCube w/ Rebel LED Lights 67 Gallon Mixed Reef, Modular LED Lights Send in the Clowns - Clown Fish Breeding 5 Gallon Fry Hatchery and 15 Gallon Clown Grow Out Tank |
#7
|
|||||
|
|||||
![]() PEX crimp tool is pretty expensive for the one small job that I would be using it for. =/
|
#8
|
|||||
|
|||||
![]() Quote:
Most hardware stores rent them for $10-$15 for 4hrs.
__________________
Ross 9 Gallon Nano, Modular LED Lights 14 Gallon BioCube w/ Rebel LED Lights 67 Gallon Mixed Reef, Modular LED Lights Send in the Clowns - Clown Fish Breeding 5 Gallon Fry Hatchery and 15 Gallon Clown Grow Out Tank |
#9
|
||||
|
||||
![]() If you have a sink nearby you could use screw on adapter on a water supply line. I rely like this one
![]() http://cdn.bulkreefsupply.com/media/...-grouped-a.jpg |