Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #1  
Old 01-01-2014, 04:03 PM
HL649 HL649 is offline
Member
 
Join Date: Mar 2009
Location: Eckville, Alberta
Posts: 85
HL649 is on a distinguished road
Default

I can hear the pump running. The lights make it look like everything is running correctly. Source water light is on, Making water light is on.
__________________
75 Gal. display with 40 Gal sump - Dual 1.5" drains, Aragonite sugar sand substrate, SWC Extreme 250 Cone Protein Skimmer, 1800L return pump, 4 AI SOL LED Lights, 250 ml pellets in a recirculating bio-pellet reactor, BRS Doser pumps for Calc & Alk, Tunze Osmolator Auto Topoff system connected Vertex Puratek RO/DI.
Reply With Quote
  #2  
Old 01-01-2014, 04:33 PM
HL649 HL649 is offline
Member
 
Join Date: Mar 2009
Location: Eckville, Alberta
Posts: 85
HL649 is on a distinguished road
Default

Ok I found the problem. The 90° fitting going into the RO canister is not allowing water to pass. There is a small metal valve built into the fitting that remains closed. If I push on the metal disc at the bottom of the fitting it will open and then allows water to flow. With water pressure on the fitting the small metal valve remains closed. It seems like if there was pressure inside the RO canister that the inside pressure might open the valve allowing the water to flow, but how do you get pressure inside the canister if the valve is closed. Is this small valve required? What if I replaced the fitting with another fitting without a valve?

I have attached a couple pictures.



__________________
75 Gal. display with 40 Gal sump - Dual 1.5" drains, Aragonite sugar sand substrate, SWC Extreme 250 Cone Protein Skimmer, 1800L return pump, 4 AI SOL LED Lights, 250 ml pellets in a recirculating bio-pellet reactor, BRS Doser pumps for Calc & Alk, Tunze Osmolator Auto Topoff system connected Vertex Puratek RO/DI.
Reply With Quote
  #3  
Old 01-01-2014, 05:13 PM
HL649 HL649 is offline
Member
 
Join Date: Mar 2009
Location: Eckville, Alberta
Posts: 85
HL649 is on a distinguished road
Default

I pulled the RO canister fittings off and found that the fitting going to the waste line did not have this small check valve on it but the fitting for the produced water did have a check valve built into the fitting. I swapped the fittings around so now both my waste line and produced water line have check valves and my inlet water source does not have a check valve. Everything seems to be working fine.

My guess is that the fitting for source water is not supposed to have a check valve and someone screwed up in the assembly of my unit. All is well now and it appears that I am going to like this unit.

Thanks for all the help. It was much appreciated.
__________________
75 Gal. display with 40 Gal sump - Dual 1.5" drains, Aragonite sugar sand substrate, SWC Extreme 250 Cone Protein Skimmer, 1800L return pump, 4 AI SOL LED Lights, 250 ml pellets in a recirculating bio-pellet reactor, BRS Doser pumps for Calc & Alk, Tunze Osmolator Auto Topoff system connected Vertex Puratek RO/DI.
Reply With Quote
  #4  
Old 01-01-2014, 05:26 PM
BlueTang<3's Avatar
BlueTang<3 BlueTang<3 is offline
Member
 
Join Date: Mar 2009
Location: Stony Plain, Alberta
Posts: 1,641
BlueTang<3 is on a distinguished road
Default

Good job ! Yet to see that
__________________
360 gallon sps reef, 180 gal sump, bubble king supermarine 300, 4xmp40Wes, 2 x 6215 tunze waveboxes, 4 ghl mitras



360 Reef Tank
Reply With Quote
  #5  
Old 01-02-2014, 09:16 PM
chef chef is offline
Member
 
Join Date: Feb 2011
Location: Whistler BC
Posts: 191
chef is on a distinguished road
Default

I have one of these awesome units and was wondering how to start the flush function. After filling my reservoir, the 3 cylinders are still full of water. is this normal?
Reply With Quote
  #6  
Old 01-02-2014, 11:00 PM
BlueTang<3's Avatar
BlueTang<3 BlueTang<3 is offline
Member
 
Join Date: Mar 2009
Location: Stony Plain, Alberta
Posts: 1,641
BlueTang<3 is on a distinguished road
Default

It will flush after it senses that the reservoir is full then once it's done then the housings will fill
__________________
360 gallon sps reef, 180 gal sump, bubble king supermarine 300, 4xmp40Wes, 2 x 6215 tunze waveboxes, 4 ghl mitras



360 Reef Tank
Reply With Quote
  #7  
Old 01-02-2014, 11:06 PM
chef chef is offline
Member
 
Join Date: Feb 2011
Location: Whistler BC
Posts: 191
chef is on a distinguished road
Default

I'm just setting my unit in the sink when I need ro/di, then the water tube is submerged in a 5g pail. how does it know when the reservoir is full? I'm thinking the canisters shouldn't be full of water when I put it away.
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 04:34 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.