Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Tank Journal

Reply
 
Thread Tools Display Modes
  #1  
Old 04-20-2013, 11:28 AM
11purewater 11purewater is offline
Member
 
Join Date: Jul 2012
Location: calgary
Posts: 580
11purewater is on a distinguished road
Default

Quote:
Originally Posted by gregzz4 View Post
My RO system has put me through the ringer lately ...

I changed the prefilter this last week, and after doing so, I heard it gurgling
Turns out it's been back-siphoning from the day I installed it, but I never caught it until now
Each time I've turned it on I've thought the purging noise I hear is just that, purging. After 11 months you'd think I would have spotted this
NOT

After the prefilter change I finally spotted the issue
The system has been sucking air in as it de-pressurizes and has been doing so as far as to drain half of my carbon canister
This is a concern as;
1 - An RO system should always be kept pressurized to protect the RO membrane
I can't fully explain this part, but I believe the theory behind it is solid

2 - Air entering the system will allow aerobic bacteria to multiply in the canisters

Now, there are tannins in our local water, so worrying about bacteria in my RO system is a waste of time, but it brought some other things to light. The one main thing is;
I've had crud in my ATO tank since day one and always thought it was from some kind of contamination. Turns out I was right

Apparently it's from the tannins in our local water, and no amount of filtering is going to help me as it's biological
I'm OK with this. At least I now know where it's coming from
I'll clean out my ATO tank every now and then, and I'll live with it

After hours and hours of online researching, multiple PMs with 11purewater, and finally a 45min phone call with him, I started to feel like I was on the right path to solving my issue

So, the problem was;
After my RO drum was full, the float valve would shut off and the waste water would stop. Nothing abnormal about that. Release the pressure from the float valve, such as using some water, and the system would back-siphon through the waste line until the Carbon canister was only half full. This is an issue as bacteria can grow in there with air

Sooooo, after many hours of testing, multiple PMs, and a much-needed phone call, I was convinced to butcher my RO system and start over

Right now I'll give a big shout out of thanks to Andy for all his help with my issues
Thanks Andy You da man

Looks like the problem is solved bud, with the addition of a valve on the permeate line even though the initial test failed
I don't understand why yet, but maybe you and I will figure it out after I send you my test notes ....

For those of you looking for pics, I started with this



I removed all of this



And I ended up with this



There will be some DI parts posted for sale after I finish this post

The system was butchered as we thought there may have been some air being introduced to the system as the water pressure dropped. Water can push against a seal and you'll have no external leaks, but remove the pressure, and air can enter through a seal as the vacuum of the pressure dropping is equalizing with atmospheric air

Long story short, I added a manual valve between my RO system and my holding tank, and all is good
Plus, of course, all of the removal of the 25 fittings I didn't need with their 50 o-rings - any 1 of which could have been a potential leak
That's more like it!Water in water out and no shenanigans
Reply With Quote
  #2  
Old 04-20-2013, 01:12 PM
Reef Pilot's Avatar
Reef Pilot Reef Pilot is offline
Member
 
Join Date: Nov 2010
Location: Langley BC
Posts: 1,883
Reef Pilot is on a distinguished road
Default

So, you have eliminated DI from your system??
__________________
Reef Pilot's Undersea Oasis: http://www.canreef.com/vbulletin/sho...d.php?t=102101
Frags FS: http://www.canreef.com/vbulletin/sho...d.php?t=115022
Solutions are easy. The real difficulty lies in discovering the problem.
Reply With Quote
  #3  
Old 04-20-2013, 04:01 PM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

Quote:
Originally Posted by 11purewater View Post
That's more like it!Water in water out and no shenanigans
Thanks again Andy
You were a very big help

Quote:
Originally Posted by Reef Pilot View Post
So, you have eliminated DI from your system??
Yes, but I never used it in the first place. I get 0 TDS with just the RO
When you look at the first pic, you'll see 2 grey valves with green handles. I plumbed it with Tees so I could use or bypass the DI. I was placing a BRS order so threw it in 'cause it's fairly cheap. I figured I might need it one day if our water went for a poop

Wanna buy it ?
Reply With Quote
  #4  
Old 04-20-2013, 04:28 PM
Reef Pilot's Avatar
Reef Pilot Reef Pilot is offline
Member
 
Join Date: Nov 2010
Location: Langley BC
Posts: 1,883
Reef Pilot is on a distinguished road
Default

Quote:
Originally Posted by gregzz4 View Post

Yes, but I never used it in the first place. I get 0 TDS with just the RO
When you look at the first pic, you'll see 2 grey valves with green handles. I plumbed it with Tees so I could use or bypass the DI. I was placing a BRS order so threw it in 'cause it's fairly cheap. I figured I might need it one day if our water went for a poop

Wanna buy it ?
I have a full RO/DI system with a dual TDS meter. What I find with mine is that sometimes my RO water will get up to about 8 or more TDS, but after DI is still always 0 or 1. That tends to happen in between water changes, when only my ATO is in use, and RO only in the kitchen. My RODI also has an auto shut-off valve, though not sure if that has anything to do with it.

When I do a water change, I also do a membrane flush, and then it comes back down to usually 0 or 1. So, my RO water TDS does vary somewhat, but my DI water is constant.

I'm in Langley, and our water here does not seem to be as low TDS as others in the Lower Mainland report. It is usually around 50 or 60 TDS out of the tap, and I find sometimes my pre-filters will clog up in only about 3 months (sometimes they are OK for 6 months or more).

I also have 2 pressure tanks (after RO, but before DI) with my system, so always have about 6 gal or so of immediate water available, which is very handy in the kitchen where we use the RO only outlet for drinking water, coffee maker, etc.
__________________
Reef Pilot's Undersea Oasis: http://www.canreef.com/vbulletin/sho...d.php?t=102101
Frags FS: http://www.canreef.com/vbulletin/sho...d.php?t=115022
Solutions are easy. The real difficulty lies in discovering the problem.
Reply With Quote
  #5  
Old 04-20-2013, 06:46 PM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

Quote:
Originally Posted by Reef Pilot View Post
I'm in Langley, and our water here does not seem to be as low TDS as others in the Lower Mainland report. It is usually around 50 or 60 TDS out of the tap, and I find sometimes my pre-filters will clog up in only about 3 months (sometimes they are OK for 6 months or more).
There's the difference
My tapwater TDS is anywhere from 12 down to as low as 7, so my RO does well on it's own
I always run my product water down the drain until the TDS creep goes away, so I am lucky that I don't need the DI
Reply With Quote
  #6  
Old 04-20-2013, 06:51 PM
Reef Pilot's Avatar
Reef Pilot Reef Pilot is offline
Member
 
Join Date: Nov 2010
Location: Langley BC
Posts: 1,883
Reef Pilot is on a distinguished road
Default

Quote:
Originally Posted by gregzz4 View Post
There's the difference
My tapwater TDS is anywhere from 12 down to as low as 7, so my RO does well on it's own
I always run my product water down the drain until the TDS creep goes away, so I am lucky that I don't need the DI
Yes, and because I run my ATO directly from my RODI to my sump, I always want 0 or at most 1 TDS all the time.
__________________
Reef Pilot's Undersea Oasis: http://www.canreef.com/vbulletin/sho...d.php?t=102101
Frags FS: http://www.canreef.com/vbulletin/sho...d.php?t=115022
Solutions are easy. The real difficulty lies in discovering the problem.
Reply With Quote
  #7  
Old 04-20-2013, 06:53 PM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

Quote:
Originally Posted by Reef Pilot View Post
Yes, and because I run my ATO directly from my RODI to my sump, I always want 0 or at most 1 TDS all the time.
Ahh
I lug the water from the drum to the ATO
Reply With Quote
  #8  
Old 04-20-2013, 06:55 PM
Reef Pilot's Avatar
Reef Pilot Reef Pilot is offline
Member
 
Join Date: Nov 2010
Location: Langley BC
Posts: 1,883
Reef Pilot is on a distinguished road
Default

Quote:
Originally Posted by gregzz4 View Post
Ahh
I lug the water from the drum to the ATO
You have my sympathies...
__________________
Reef Pilot's Undersea Oasis: http://www.canreef.com/vbulletin/sho...d.php?t=102101
Frags FS: http://www.canreef.com/vbulletin/sho...d.php?t=115022
Solutions are easy. The real difficulty lies in discovering the problem.
Reply With Quote
  #9  
Old 04-20-2013, 06:54 PM
11purewater 11purewater is offline
Member
 
Join Date: Jul 2012
Location: calgary
Posts: 580
11purewater is on a distinguished road
Default

Quote:
Originally Posted by gregzz4 View Post
Thanks again Andy
You were a very big help


Yes, but I never used it in the first place. I get 0 TDS with just the RO
When you look at the first pic, you'll see 2 grey valves with green handles. I plumbed it with Tees so I could use or bypass the DI. I was placing a BRS order so threw it in 'cause it's fairly cheap. I figured I might need it one day if our water went for a poop

Wanna buy it ?
Anytime!
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 07:57 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.