I've been messin' around with the flush valve on the RO unit. I've found that I can totally shut off the waste water line, and then I get nearly 100gpd, based on some math.
I think I'll run it around 80gpd and flush it every couple of hours.
Otherwise, if I use the valve in it's normal position, I only get about 40gpd, with a lot of waste. No point wasting all that water with the incoming TDS @ only 7-8ppm.
Reply With Quote
  #2  
Old 01-14-2012, 10:49 PM
hillegom hillegom is offline
Member
 
Join Date: Nov 2008
Location: Surrey
Posts: 1,998
hillegom is on a distinguished road
Default

Did you install a flow restrictor in the line? If the correct one is in there, you will get 100gpd with 400 gal waste. The flush valve should only be used to back flush the membrane, otherwise it should be shut off.
If you do not get 100gpd form a 100gpd membrane, then either your feed water pressure is too low, or the temp of incoming water is too cold.
I don't have a flush valve, the last membrane lasted 3 yrs. I have been debating whether I should instal one, but some co. speak against flushing.
So until I can research more, I won't backflush.
Reply With Quote
  #3  
Old 01-14-2012, 11:13 PM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

Ya, I've been debating the whole idea of playing with the valve. With it completely closed, I'm not getting 100gpd.
I think I'll get a restrictor as this unit didn't come with one, neither inline nor in the output elbow.
Thanks again

Last edited by gregzz4; 01-14-2012 at 11:22 PM.
Reply With Quote
  #4  
Old 01-15-2012, 12:18 AM
hillegom hillegom is offline
Member
 
Join Date: Nov 2008
Location: Surrey
Posts: 1,998
hillegom is on a distinguished road
Default

Very unusual not to have a restrictor, it creates the proper backpressure so water gets fed through the membrane. I wonder if it already comes with one installed. Some restrictors are inside of the quarter inch black poly tube. It should be right at the connection where the black tube comes out of the ro membrane canister. It will look like this:
http://www.marinedepot.com/Flow_Rest...RORAFR-vi.html
And is pushed into the black tube so only the shoulder is sticking out. Mine is coloured black and its hard to see unless youknow its there.
Reply With Quote
  #5  
Old 01-15-2012, 12:25 AM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

It was definately missing. I checked all the packaging and the white tubing that came with this unit.
I just got back from J&L and there is now a 100gpd in the black line leaving the RO membrane.
I'll report back once I do some more math.
And once again, Thanks hillegom, you may have solved another issue for me
Down the road I'll change over to the inline style when I go with a 75GPD membrane. I've heard the 75s are more efficient.
Reply With Quote
  #6  
Old 01-15-2012, 02:05 PM
Buckeye Field Supply Buckeye Field Supply is offline
Junior Member
 
Join Date: Nov 2011
Location: Ohio
Posts: 20
Buckeye Field Supply is on a distinguished road
Default

A 75 gpd membrane with a proper flow restrictor will still produce apx. 4 parts waste water to 1 part purified water, so it's no more "efficient" in this regard.

What a 75 will do much better however, is clean the water. Here are some spec's for you (the 24 - 100 gpd membranes are Filmtec brand):



Russ
Reply With Quote
  #7  
Old 01-15-2012, 04:58 PM
gregzz4's Avatar
gregzz4 gregzz4 is offline
On Hiatus
 
Join Date: Oct 2011
Location: Burnaby, B.C.
Posts: 4,890
gregzz4 will become famous soon enough
Default

Thanks for that Russ. I don't believe Vertex's claims of 98% rejection on the 100gpd I bought, but with 8ppm in and 0ppm out, guess it doesn't matter anyway. Makes me wonder if I'll ever need the DI.
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 06:51 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.