#1
|
|||||
|
|||||
![]() Here's a pick of the unit to show where the gauge Is:
![]()
__________________
Robb |
#2
|
||||
|
||||
![]() I would change the particle and the two carbon filters. Most likely everything is just plugged up.
|
#3
|
||||
|
||||
![]() Oops Just one particle and one carbon.
Dont change the two DI |
#4
|
|||||
|
|||||
![]() There's water getting through the prefilter and carbon but nothing but a bit of waste waters getting through the membrane.
__________________
Robb |
#5
|
||||
|
||||
![]() So how long have you been running this unit with the same filters?
As Marko said, try running water through without the filters. However, disconnect the RO membrane. You do not want to run chlorine water through it. Test all the hoses to look for an obstruction. If everything is ok, then put the filters back in and connect up the RO membrane backwards to flush it. Don't switch the ro water with the waste water, just switch the ro in to ro out, your good water. Then flush for 2-3 min. If you have been running the filters, the particle and the carbon for over a year, I would switch them for new ones. |
#6
|
|||||
|
|||||
![]() Membrane is done, I can't get any water through it, the other canisters have flow through them, no blockages.
New membrane and all new filters from SpectaPure - $225 plus Nem membrane and all new filters from BRS - $76.70
__________________
Robb |
#7
|
||||
|
||||
![]() Did you try to backflush the membrane cartridge?
|
![]() |