No you cant use XP-G and XP-E in the same circuit if you want them at 100% XP-E is 1000mA and XP-G is 1500mA so you would blow the XP-Es.

XP-G outputs 139 lumens and XP-E 122 that is running them at 350mA. Cree doesnt have data fro XP-E at full power which is weird. However the XP-G output 463 lumens at full power.

For that size of tank i would recommend 2 pods each holding 28 LEDs so a 56 LED setup. Since you are 20 inches wide you could use any of our 6 inch heatsinks (6 x 9 or 6 x 12). Or I am getting in some larger 10 x 10 which gives nice coverage. 50/50 royal blue to white gives you a color around 14K or you can go 60/40 for a 20K bluer look. We also have regular blues now so you can mix Royal Blue and regular Blue for more spectrum and maybe throw in an additional Red if you want.

Martin


Quote:
Originally Posted by SteveConn View Post
Martin, what would be recommended for a 72g tank that is 36 long, 20 wide (front to back depth) and 25 inches deep (from top to bottom)?

What kind of difference in brightness between the white XP-E and XP-G? Can they be used together in the same circuit (like a standard series of XP-E)? I dont know if you can use 5W @ 100% with 3W in the same circuit.

Thanks

Steve
__________________
Western Database - Custom database, software design and cloud hosting.
 

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 07:24 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.