Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #1  
Old 06-23-2011, 05:08 AM
hdrob hdrob is offline
Junior Member
 
Join Date: Mar 2011
Location: Smithers
Posts: 5
hdrob is on a distinguished road
Default

I was asking if mark's setup was possible or if anyone had it setup like that.

One hole per overflow with 2 corner overflows.

Thanks Mark!
Reply With Quote
  #2  
Old 06-23-2011, 05:54 AM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

Only issue I could see with running primary in one and emergency drain in the other overflow is water becoming stagnant in emergency's chamber.

Was going to raise the lip height of the overflow with emergency but never did. What I ended up doing was drill a hole in the side of the emergency drain standpipe so I have a small but continuous movement of water. My sump can easily handle the full volume of the chamber in a power outage but I still drilled it up near the top of the standpipe and have a 1/4"OD tubing running to the bottom. Since hole is near top, that's my siphon break.

I'm also running a 20g fuge separate from my sump and just tee's the primary drain. About 200gph to the fuge rest to the sump. Here's my post on converting from dual Dursos to the Herbie.
__________________
my tank

Last edited by mark; 06-23-2011 at 06:09 AM. Reason: added link
Reply With Quote
  #3  
Old 06-23-2011, 06:20 AM
hdrob hdrob is offline
Junior Member
 
Join Date: Mar 2011
Location: Smithers
Posts: 5
hdrob is on a distinguished road
Default

I was planning on raising the emergency overflow lip.

Is there a benefit to letting a small amount of water flow through emergency overflow?
Reply With Quote
  #4  
Old 06-23-2011, 06:45 AM
mark's Avatar
mark mark is offline
Member
 
Join Date: Nov 2002
Location: Edmonton AB
Posts: 4,212
mark is on a distinguished road
Default

think it's a either or type thing. Raise the lip or if both OFs same height, move the water a bit. For the emergency drain line itself, can't see advantage of running water through it, though see some conventional Herbies always running a little moist.

btw since you only have a single hole in each, seems a Bean is out.
__________________
my tank
Reply With Quote
  #5  
Old 06-23-2011, 02:53 PM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

Why not use all drilled holes for drains so you can setup a dual herbie, then just run your return behind and over your tank.

And the dart isn't a bad size for the tank, a little big but nothing it couldn't handle. Personally I would go with a good quality internal pump for noise and reliability but that's just my personal preference.

Last edited by sphelps; 06-23-2011 at 02:55 PM.
Reply With Quote
  #6  
Old 06-23-2011, 03:05 PM
mike31154's Avatar
mike31154 mike31154 is offline
Member
 
Join Date: Jul 2008
Location: Vernon
Posts: 2,073
mike31154 will become famous soon enough
Default

The way he described his overflows (post #8), the extra, or return holes are drilled outside of them. He'd have modify or move the overflows to include these outside holes (or plug them?) to do the Herbie using all drilled holes.
__________________
Mike
77g sumpless SW
DIY 10 watt multi-chip LED build http://www.canreef.com/vbulletin/showthread.php?t=82206

Last edited by mike31154; 06-23-2011 at 03:07 PM.
Reply With Quote
  #7  
Old 06-23-2011, 03:25 PM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

Quote:
Originally Posted by mike31154 View Post
The way he described his overflows (post #8), the extra, or return holes are drilled outside of them. He'd have modify or move the overflows to include these outside holes (or plug them?) to do the Herbie using all drilled holes.
IC, in this case I would personally wouldn't use a standard herbie design, I think using a second overflow with the purpose of emergency only will lead to problems as already stated such as stagnant water even if it's higher as water will still sit around the bulkhead which could lead to mold growth and that algae smell. What I would do is use the one overflow as a primary to take the majority of the flow, you can still set it up with a gate valve but adjust it so a small amount of flow still goes through the second overflow which would have a durso standpipe. Setup the durso so it has a small siphon break hole and a longer downspout, if the primary clogs up the durso will siphon under the higher load to prevent tank overflow. The second overflow will need to be slightly higher but nothing significant, a layer of silicone should be sufficient.
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 01:08 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.