Quote:
Originally Posted by BCOrchidGuy
What kind of media are you using, I'd start with about 30 bubbles a minute and then measure your pH and aim for the recomended pH the media manufacturer suggests. I used ARM and found that 19 bubbles a minute gave me a pH of 7.48 or 7.49 the ARM packaging said to get a pH of 7.5,
Doug
|
one problem to quantify 30 bubbles per minuit you have to also state a effulent flow.
I started mine at 60 bubbles per min with a effulent flow of 100 ml/min but this will also depend on tank size.. if you want to start at 30 bubbles per min I would sugest starting with a efulent flow of 50ml/min and then adjust your effulent flow to set your PH. this will alow you to have ahigher flow for a Ca demand heavy tank. and after you get that set you can play with both to fine tune it.
Steve
__________________

*everything said above is just my opinion, and may or may not reflect the views of this BBS, its Operators, and its Members. If cornered on any “opinion” I post I will totally deny having ever said this in a Court of Law…Unless I am the right one*