#1
|
|||||
|
|||||
|
Quote:
PRV should be fairly near your water meter, just downstream, although mine is quite a ways down and my outdoor tap is plumbed in before it to take advantage of full city pressure for the garden. http://www.plumbersurplus.com/images...-5734-3809.jpg
__________________
Mike 77g sumpless SW DIY 10 watt multi-chip LED build Last edited by mike31154; 06-07-2010 at 03:58 PM. |
|
#2
|
|||||
|
|||||
|
Quote:
I spent 5 bucks on a needle valve and used it to adjust my inlet PSI but I run two membrains in parallel Steve
__________________
*everything said above is just my opinion, and may or may not reflect the views of this BBS, its Operators, and its Members. If cornered on any “opinion” I post I will totally deny having ever said this in a Court of Law…Unless I am the right one*Some strive to be perfect.... I just strive. |
|
#3
|
|||||
|
|||||
|
NO he mentioned the PRV as something someone could adjust to get your house plumbing at a higher PSI. The PRV is located near you main shut off I guess (still havent went looking for mine).
As for the GPD ratings being multiple on Dow membranes, when I look at the dow filmtec membranes are not sold like this. I believe that virtually any ro membrane will produce more GPD when higher pressure is applied. The problems with doing so is that the rejection rating will be affected. If you want rejection ratings similar (I actually find them better) then advertised then you should run them to spec. |
|
#4
|
|||||
|
|||||
|
Quote:
Steve
__________________
*everything said above is just my opinion, and may or may not reflect the views of this BBS, its Operators, and its Members. If cornered on any “opinion” I post I will totally deny having ever said this in a Court of Law…Unless I am the right one*Some strive to be perfect.... I just strive. |
|
#5
|
|||||
|
|||||
|
Yes I'm talking of the dow filmtec membranes (the best IMO).
How ever I only know of the 50,75,100 and 150gpd membranes. Never head of the 100/160? |
|
#6
|
|||||
|
|||||
|
Quote:
back unsaviory vendors were using this to there advantage and not telling people, so they would sell the 75@60 as a 90/160 , as at 60 PSI it is a 90gpd and at 100 PSI it was 160 GPDand it was cheeper than buying the 100 which would give you a true 100@50psi. then they would blame the lower output on the temp of your water. since the membrain is rated for up to 150 PSI this wasn't a problem as long as people knew what they had and that at 50 PSI they only had a 75 gal membrain. another company started relabling dow 75 and 100s as 100/160's at 50 and 90 psi, but it was a dow membrain just relabled. mine are dow 100's which I run at 120 PSI giving me a total output of more than 360 GPD when I measured it last. I ran them this way for 2 years and did a 5 min backflush after every use, but they have been dry since I moved now so I will have to buy new ones. Steve
__________________
*everything said above is just my opinion, and may or may not reflect the views of this BBS, its Operators, and its Members. If cornered on any “opinion” I post I will totally deny having ever said this in a Court of Law…Unless I am the right one*Some strive to be perfect.... I just strive. |
![]() |