Quote:
Originally Posted by JonT View Post
Few ways to deal with this. Either way, your going to get bubbles if you are either breaking the surface of the water, or you have air in the drain line.

Bubble towers work great. Grab a 4" piece (bit taller than the Sump) of PVC and a 3" piece(couple inches shorter than the water line). You want a 1 - 2 inch solid bottom. This will stop the water from simply flowing under it. Above that 1-2 inches, drill/cut openings. The holes need to be lower than the 3" piece of PVC.

Drop the 3 inch on the bottom of the sump. Slide the 4" piece with its holes over that, and stick the drain line into the middle. This creates a baffle system. The salt spray will stay contained in the 4" piece.

Or, the easier way (not the quietest way) is to put a T in the drain line right at the surface of the water level. One end goes down to the sump, and one goes out horizontal. This gives the bubbles a spot to run out. Most will pop in the horizontal run if it is long enough. Some will still be going out the bottom, but not as many.


Or, go with the Herbie method that uses a siphon. There is no air in the drain line, thus no bubbles. And dead quiet.
good advice there except for one tiny detail........"herbie" method is not a siphon......it is purely a gravity feed........like your bathtub.....thats why its pretty much "fail-safe"
__________________
260g mixed reef, 105g sump, water blaster 7000 return, Bubble King SM 300 skimmer, Aqua Controller Jr, 4 radions, 3 Tunze 6055s,1 tunze 6065, 2 Vortech MP40s, Vortech MP20, Tunze ATO, GHL SA2 doser, 2 TLF reactors (1 carbon, 1 rowa). http://www.canreef.com/vbulletin/showthread.php?t=50034 . Tank Video here http://www.vimeo.com/2304609 and here http://www.vimeo.com/16591694
Reply With Quote
  #2  
Old 05-11-2010, 04:52 PM
JonT JonT is offline
Member
 
Join Date: May 2010
Location: Toronto
Posts: 74
JonT is on a distinguished road
Default

Quote:
Originally Posted by fishytime View Post
good advice there except for one tiny detail........"herbie" method is not a siphon......it is purely a gravity feed........like your bathtub.....thats why its pretty much "fail-safe"
Okay, modified Herbie method AKA BeAnAnimal. This will move a ton of water, and do it dead quiet.

http://www.beananimal.com/projects/s...ow-system.aspx
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 09:42 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.