Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > DIY

Reply
 
Thread Tools Display Modes
  #1  
Old 01-20-2010, 01:40 PM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

Durso standpipes should be one size bigger than the drain to work properly, so if you're using 1.5" pipe for the drain, your durso standpipe should be 2". This should fix your problem.

FYI many plumbing stores will sell PVC pipe by the foot.
Reply With Quote
  #2  
Old 01-20-2010, 03:20 PM
christyf5's Avatar
christyf5 christyf5 is offline
Staff
 
Join Date: Aug 2001
Location: Nanaimo
Posts: 9,175
christyf5 is on a distinguished road
Default

Quote:
Originally Posted by sphelps View Post
Durso standpipes should be one size bigger than the drain to work properly, so if you're using 1.5" pipe for the drain, your durso standpipe should be 2". This should fix your problem.

FYI many plumbing stores will sell PVC pipe by the foot.
Unfortunately we don't have many plumbing stores. We have Home Hardware. Home Depot doesn't sell it (they only sell the type for irrigation, tons of holes in it) and I'm not sure about Rona, they seem more like a "I need to hang a picture, do you have nails and an apartment sized hammer?" type of store, either that or we have a mini-Rona
__________________
Christy's Reef Blog

My 180 Build

Every electronic component is shipped with smoke stored deep inside.... only a real genius can find a way to set it free.
Reply With Quote
  #3  
Old 01-20-2010, 03:27 PM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

Quote:
Originally Posted by christyf5 View Post
Unfortunately we don't have many plumbing stores. We have Home Hardware. Home Depot doesn't sell it (they only sell the type for irrigation, tons of holes in it) and I'm not sure about Rona, they seem more like a "I need to hang a picture, do you have nails and an apartment sized hammer?" type of store, either that or we have a mini-Rona
Well either way you should be using a 2" standpipe to match your 1.5" drain. You could always use 2" ABS which may be easier to find in your area, it also typically comes in 4 foot lengths.
Reply With Quote
  #4  
Old 01-20-2010, 03:37 PM
christyf5's Avatar
christyf5 christyf5 is offline
Staff
 
Join Date: Aug 2001
Location: Nanaimo
Posts: 9,175
christyf5 is on a distinguished road
Default

Quote:
Originally Posted by sphelps View Post
Well either way you should be using a 2" standpipe to match your 1.5" drain. You could always use 2" ABS which may be easier to find in your area, it also typically comes in 4 foot lengths.
Oh I always thought ABS was bad?
__________________
Christy's Reef Blog

My 180 Build

Every electronic component is shipped with smoke stored deep inside.... only a real genius can find a way to set it free.
Reply With Quote
  #5  
Old 01-20-2010, 03:41 PM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

Quote:
Originally Posted by christyf5 View Post
Oh I always thought ABS was bad?
No, that's a common myth. ABS is completely potable and safe for aquariums. ABS is used in drains because it has a higher resistance to chemicals. Also most of the plastic parts already in your aquarium like pumps and magnet cleaners are made from ABS.
Reply With Quote
  #6  
Old 01-20-2010, 03:45 PM
christyf5's Avatar
christyf5 christyf5 is offline
Staff
 
Join Date: Aug 2001
Location: Nanaimo
Posts: 9,175
christyf5 is on a distinguished road
Default

Oh! Well thats great info!

So I'm at a bit of a loss with the photo you posted of the single herbie. Why does it have 1.25" pipe in it? Does the 1.25" pipe go all the way through, how is it affixed in the 2" pipe? And whats going on with the gate valve?

Sorry for all the questions, apparently I need more caffeine
__________________
Christy's Reef Blog

My 180 Build

Every electronic component is shipped with smoke stored deep inside.... only a real genius can find a way to set it free.
Reply With Quote
  #7  
Old 01-20-2010, 04:18 PM
sphelps's Avatar
sphelps sphelps is offline
Member
 
Join Date: May 2006
Location: Lyalta, East of Calgary
Posts: 4,777
sphelps is on a distinguished road
Default

Quote:
Originally Posted by christyf5 View Post
So I'm at a bit of a loss with the photo you posted of the single herbie. Why does it have 1.25" pipe in it? Does the 1.25" pipe go all the way through, how is it affixed in the 2" pipe? And whats going on with the gate valve?
The 1.25" pipe goes all the way through (it's one piece) and acts as the secondary or back up drain. It's supported inside the 2" pipe by the bushing.

The primary drain is created by the 2" pipe. Water flows in between the 2" and 1.25" pipe and then through the gate valve. The gate valve is used to match the flow rate to the return pump and adjust the water level in the overflow box to just below the top of the 1.25" pipe. It's just like a standard herbie but the back up drain is inside the primary.

Make sense?
Reply With Quote
  #8  
Old 07-25-2012, 02:18 PM
StirCrazy's Avatar
StirCrazy StirCrazy is offline
Member
 
Join Date: Oct 2001
Location: Kamloops, BC
Posts: 7,872
StirCrazy is on a distinguished road
Default

Quote:
Originally Posted by christyf5 View Post
Oh I always thought ABS was bad?

Christy, we went throught this 10 years ago......

Steve
__________________
*everything said above is just my opinion, and may or may not reflect the views of this BBS, its Operators, and its Members. If cornered on any “opinion” I post I will totally deny having ever said this in a Court of Law…Unless I am the right one*

Some strive to be perfect.... I just strive.
Reply With Quote
  #9  
Old 03-08-2010, 11:12 PM
banditpowdercoat's Avatar
banditpowdercoat banditpowdercoat is offline
Member
 
Join Date: Oct 2007
Location: 100 mile hse BC
Posts: 2,568
banditpowdercoat is on a distinguished road
Default

Durso's will allways make some noise but ya if pipe is to small, it will make more noise.

I will never do another tank unless it's Herbie style. In fact, Combine them for 3 drains. 1 Herbie gate valved, another Durso, full open to take the excess the gate valved one doesn't and a Emergency line.

I want to change my tank now, but I can't get behind it to re-plumb my drains
__________________
Dan Pesonen


Umm, a tank or 5
Reply With Quote
  #10  
Old 07-25-2012, 01:09 AM
Seth81's Avatar
Seth81 Seth81 is offline
Member
 
Join Date: Dec 2011
Location: Calgary
Posts: 189
Seth81 is on a distinguished road
Default

Quote:
Originally Posted by banditpowdercoat View Post
Durso's will allways make some noise but ya if pipe is to small, it will make more noise.

I will never do another tank unless it's Herbie style. In fact, Combine them for 3 drains. 1 Herbie gate valved, another Durso, full open to take the excess the gate valved one doesn't and a Emergency line.

I want to change my tank now, but I can't get behind it to re-plumb my drains

If you do go Herbie, just don't do what I did... see my post in DIY "Herbie design fail"
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 10:59 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.