Quote:
Originally Posted by mark View Post
You must be afraid to go near your tank.
You've got that right. Scaring the crap out of me.

Quote:
[Measure between the reflector and a ground point, right a receptacle. Rather than your lights being the ground, they might be the leak.
Will check that today.
__________________
Doug
Reply With Quote
  #32  
Old 04-06-2008, 02:05 PM
Doug's Avatar
Doug Doug is offline
Rest In Peace
 
Join Date: Aug 2001
Location: Kamloops BC
Posts: 4,920
Doug has disabled reputation
Default

Quote:
Originally Posted by asmodeus View Post
Hey there doug just reading your post and may be you should check your GFI plug to make sure that it is grounded first off , if not its just like a normal plug..
Yes its grounded. Both are.
__________________
Doug
Reply With Quote
  #33  
Old 04-06-2008, 05:12 PM
banditpowdercoat's Avatar
banditpowdercoat banditpowdercoat is offline
Member
 
Join Date: Oct 2007
Location: 100 mile hse BC
Posts: 2,568
banditpowdercoat is on a distinguished road
Default

Quote:
Originally Posted by KrazyKuch View Post

Once you've had 600 Volts surge through your body, 120 volts seems like child's play!!!

That is sooo true LOL. 1500v rocks your world too, got some scars to prove that. LOL

How old are your pumps? Id be calling Tunze. 35v leakage is NOT COOL. Sounds like the case on the pump has a defect in it, expoing the windings to the water. If the GFCI tripped plugging the Tunze in when ground probe installed.

The light shade should be grounded, and you stated that you got shocked with light out as well, so I could rule the light out. I have seen instances in HO-T12 lights, where the ballast would induce 40-50V into the reflector/shade. But that was with a Magnetic ballast installed in the light, inducing a voltage into the shade, not acctually shorting or leaking. Anything that has a magnetic field, can induce electricity into metal near it.
__________________
Dan Pesonen


Umm, a tank or 5

Last edited by banditpowdercoat; 04-06-2008 at 05:19 PM.
Reply With Quote
  #34  
Old 04-06-2008, 05:30 PM
spreerider spreerider is offline
Member
 
Join Date: Mar 2008
Location: port alberni
Posts: 170
spreerider is on a distinguished road
Default

Quote:
Hey there doug just reading your post and may be you should check your GFI plug to make sure that it is grounded first off , if not its just like a normal plug
GFI only compares the current through the 'hot' wire against the current in the 'Neutral', if the current through them is different as in some current is leaking to ground, the GFI detects the difference and trips, so it actually doesnt need the ground connection to work its just safer to have it properly grounded as this will reduce the shock risk for a person handling the device.
Reply With Quote
  #35  
Old 04-06-2008, 07:09 PM
Doug's Avatar
Doug Doug is offline
Rest In Peace
 
Join Date: Aug 2001
Location: Kamloops BC
Posts: 4,920
Doug has disabled reputation
Default

120 or less is not kids play when its your forehead thats sparking.
__________________
Doug
Reply With Quote
  #36  
Old 04-06-2008, 07:20 PM
Aquattro's Avatar
Aquattro Aquattro is offline
Just a guy..
 
Join Date: Aug 2001
Location: Victoria, BC
Posts: 18,053
Aquattro is a jewel in the roughAquattro is a jewel in the roughAquattro is a jewel in the roughAquattro is a jewel in the rough
Default

Quote:
Originally Posted by Doug View Post
120 or less is not kids play when its your forehead thats sparking.
Doug, I know this all serious and stuff, but I just can't help laughing my a$$ off !! Maybe you need rubber gloves and a rubber hat!
__________________
Brad
Reply With Quote
  #37  
Old 04-06-2008, 08:42 PM
Toxik Toxik is offline
Member
 
Join Date: Feb 2008
Location: Abbotsford
Posts: 50
Toxik is on a distinguished road
Default

When checking for stray voltage with a volt meter, where do you put the probes. In the water? I've never had to do this but am still curious of the procedure.
Reply With Quote
  #38  
Old 04-06-2008, 09:09 PM
Doug's Avatar
Doug Doug is offline
Rest In Peace
 
Join Date: Aug 2001
Location: Kamloops BC
Posts: 4,920
Doug has disabled reputation
Default

Quote:
Originally Posted by Aquattro View Post
Doug, I know this all serious and stuff, but I just can't help laughing my a$$ off !! Maybe you need rubber gloves and a rubber hat!

Thats me if it gets me again.
__________________
Doug
Reply With Quote
  #39  
Old 04-06-2008, 09:13 PM
Doug's Avatar
Doug Doug is offline
Rest In Peace
 
Join Date: Aug 2001
Location: Kamloops BC
Posts: 4,920
Doug has disabled reputation
Default

Quote:
Originally Posted by Toxik View Post
When checking for stray voltage with a volt meter, where do you put the probes. In the water? I've never had to do this but am still curious of the procedure.
I started out, {because it was the grounded pendant and water contact that got me}, with a measure from the pendant, {red probe} to the water [black probe, common}. When the ground probe was installed, I dont get a reading now.

Unless you forget the ground is out and you're forehead arcs across to the pendant.
__________________
Doug
Reply With Quote
  #40  
Old 04-06-2008, 09:15 PM
Doug's Avatar
Doug Doug is offline
Rest In Peace
 
Join Date: Aug 2001
Location: Kamloops BC
Posts: 4,920
Doug has disabled reputation
Default

Quote:
Originally Posted by Doug View Post
Hi Kevin, Thanks for jumping in here.

My breakers say

Arc Fault
& GFCI
Breaker
Type BRAF
<--- GF Test AF--->

Anyways I,m off to check the meter. As I posted, everything seems to add its share of current.

So it reads almost 122v. Not enough out for the 9 volts. Would it sense a 9v battery in a digital thermometer?
Just to clarify that up.
Attached Images
File Type: jpg arc breaker.jpg (16.9 KB, 17 views)
__________________
Doug
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 08:16 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.