Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #1  
Old 02-09-2008, 12:54 AM
Skimmerking's Avatar
Skimmerking Skimmerking is offline
acanthastrea freak
 
Join Date: Jun 2002
Location: Virden, Manitoba
Posts: 5,690
Skimmerking is on a distinguished road
Send a message via ICQ to Skimmerking Send a message via MSN to Skimmerking
Default

yes that is right its just easy to control the kalk to what ever i need so Im not getting much if im not using it with a top off you are just adding it and causing the levels to go up. with it this way if you top off is not enough then turn up the Kalk
__________________
180 starfire front, LPS, millipora
Doesn't matter how much you have been reading until you take the plunge.
You don't know as much as you think.
Reply With Quote
  #2  
Old 02-09-2008, 02:50 AM
atcguy atcguy is offline
Member
 
Join Date: Mar 2005
Location: White rock
Posts: 167
atcguy is on a distinguished road
Default

cool, seems like a good plan. enjoy the kalk mixer....
__________________
Gerad
White Rock
Reply With Quote
  #3  
Old 02-09-2008, 05:04 AM
untamed's Avatar
untamed untamed is offline
Member
 
Join Date: Feb 2005
Location: Coquitlam
Posts: 2,248
untamed is on a distinguished road
Default

Quote:
Originally Posted by asmodeus View Post
yes that is right its just easy to control the kalk to what ever i need so Im not getting much if im not using it with a top off you are just adding it and causing the levels to go up. with it this way if you top off is not enough then turn up the Kalk
Yup. Exactly. Since often Kalk can't keep up with Ca/Alk demand on it's own, people frequently end up matching the Kalk input to their evaporation (which is the maximum)

The problem is that only works if your needs are that high. Somehow, it gets misunderstood that Kalk should just be used as evaporative replacement without regard to Ca/Alk demand and that gets people in trouble.

Mine is hooked up just like yours. Completely independent of the evap replacement system. I just happen to use a pump to dose what I want, and only dose at night.

I would assume that the Kalk in your reactor is the same as the Kalk you used to make in the tub. A saturated solution is a saturated solution. (assuming the temp is the same...)
__________________
400 gal reef. Established April, 2007. 3 Sequence Dart, RM12-4 skimmer, 2 x OM4Ways, Yellow Tang, Maroon Clown (pair), Blonde Naso Tang, Vlamingi Tang, Foxface Rabbit, Unicorn Tang, 2 Pakistani Butterflies and a few coral gobies

My Tank: http://www.canreef.com/vbulletin/showthread.php?t=28436
Reply With Quote
  #4  
Old 02-10-2008, 12:12 AM
PoonTang's Avatar
PoonTang PoonTang is offline
Member
 
Join Date: Mar 2007
Location: Ladysmith BC
Posts: 1,071
PoonTang is on a distinguished road
Default

Quote:
Originally Posted by asmodeus View Post
yes that is right its just easy to control the kalk to what ever i need so Im not getting much if im not using it with a top off you are just adding it and causing the levels to go up. with it this way if you top off is not enough then turn up the Kalk
What are you using for a pump? or are you connected directly to your RO unit?
Reply With Quote
  #5  
Old 02-10-2008, 12:44 AM
Skimmerking's Avatar
Skimmerking Skimmerking is offline
acanthastrea freak
 
Join Date: Jun 2002
Location: Virden, Manitoba
Posts: 5,690
Skimmerking is on a distinguished road
Send a message via ICQ to Skimmerking Send a message via MSN to Skimmerking
Default

no there is no pump running the reactor. If you look at the pic on this thread there is a TEE on the top of the reactor on the right side of the TEE there is a line that is from my RO/DI the one on the bottom it feeds my float switch in the sump. and you see the line going to the reactor, from there see the smal gate valve that is there to only allow in so much water to go through it So i have control on how much will come out. If I want 3 drips per sec i just tunr it and watch the out put line and adjust it until i have 3 drips per second. and this way if I didnt have the gate valve there the reactor would explode. The reason I have it this way so what running the reactor this way will give me the proper level in the tank as the tank requires more CAL / ALk i will turn up the reactor.

So at the end of the day, what ever the reactor doesn't give the sump the Float switch will finish off. I hope that this meake s sense...
__________________
180 starfire front, LPS, millipora
Doesn't matter how much you have been reading until you take the plunge.
You don't know as much as you think.
Reply With Quote
  #6  
Old 02-10-2008, 11:33 PM
PoonTang's Avatar
PoonTang PoonTang is offline
Member
 
Join Date: Mar 2007
Location: Ladysmith BC
Posts: 1,071
PoonTang is on a distinguished road
Default

Very nice setup. The only thing i would be worried about was if the float were to stick/fail then you would be putting endless amounts of makeup water into your tank. Have heard many horror stories of this happening. I would suggest putting in a back up float and a solenoid valve that cuts off the FW to your RODI unit.
Reply With Quote
  #7  
Old 02-10-2008, 11:56 PM
Skimmerking's Avatar
Skimmerking Skimmerking is offline
acanthastrea freak
 
Join Date: Jun 2002
Location: Virden, Manitoba
Posts: 5,690
Skimmerking is on a distinguished road
Send a message via ICQ to Skimmerking Send a message via MSN to Skimmerking
Default

Poon I do have a back up I should have said something. oops

I have it on my RO/DI its a solenid on there in case it mulfunctions
__________________
180 starfire front, LPS, millipora
Doesn't matter how much you have been reading until you take the plunge.
You don't know as much as you think.
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 06:43 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.