The fan should help, but then you're relying on the doorjambs and windows and furnace intake to replace the air that is drawn out.

75%-80% humidity is going to end up being a real problem for you. When it starts to get cold outside you'll see what I mean - the outside walls and windows will get a heavy condensation form, especially at night, and this in turn causes things like mildew and mold. In the summer it's not so bad, in fact you may even get to like the humidity - but yeah ultimately 75% is way too much for our climate.

I know this because humidity has been a problem I've been battling for years with my tanks. In my old house, the outside walls were 2x4 and this wasn't adequate insulation against the temperature differentials. So I built a new house using post-2000 building code rules and guess what, now houses are so air-tight in their quest to be more energy-efficient, that it's the same problem all over again (just due to a different reason) - the house just doesn't have enough air turnover to shed the excessive humidity.

Anyhow, the fan should work. It's not the best solution for our climate but it will vent the wet air out, which is what you want.

The ultimate solution is to use a HRV ("Heat Recovery Ventilator") instead of an exhaust fan. The concept is basically the same (ie. venting air to the outside) but with two important details: 1) The air that is vented outside is replaced by air from the outside, thus removing the "air deficit" that a fan alone would create, and 2) It uses an heat exchanger to use the outgoing air to preheat the incoming air (which is important when it's -40 outside). They recover something like 85% of the heat of the outgoing air, which is good when it comes time to look at your monthly heating bills.

Anyhow hope this info helps. Definitely do a fan or something, 460 gallons evaporating into your house will have an adverse effect.
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!

Last edited by Delphinus; 08-30-2007 at 10:05 PM.
Reply With Quote
  #2  
Old 08-30-2007, 08:08 PM
littlesilvermax's Avatar
littlesilvermax littlesilvermax is offline
Member
 
Join Date: Oct 2004
Location: Winnipeg
Posts: 779
littlesilvermax is on a distinguished road
Default

I have 350+ gallons in my house and never get above 55% or so. I am usually at around 40%.

You need an HRV or else be prepared to get mold. Then you may as well just burn the house down.
__________________
250 BB Starphire SPS, clams, & zoos
3 x 250 DE, IC 660 W/T5s
OM 4-way, Hammerhead Pump
Calcium, Kalk, RO filters, magnesium, Excellent prices
Reply With Quote
  #3  
Old 08-30-2007, 08:21 PM
phillybean phillybean is offline
Member
 
Join Date: Nov 2006
Location: Kelowna
Posts: 270
phillybean is on a distinguished road
Default

What about dehumidifiers? I think I spelled that wrong but you know what I mean.

http://cgi.ebay.ca/Soleus-CFM40-Port...QQcmdZViewItem
Reply With Quote
  #4  
Old 08-30-2007, 08:48 PM
Joe Reefer's Avatar
Joe Reefer Joe Reefer is offline
Masterbaiter
 
Join Date: Jan 2005
Location: Edmonton
Posts: 1,205
Joe Reefer is on a distinguished road
Send a message via MSN to Joe Reefer
Default

HRV's are only an option to reducing heating costs by recovering some of the heat being exhausted. To elimate moisture issues you must "exchange air" simple as that.

If you are truly serious about not having any moisture issues, a make-up air system should be considered. This would include a small furnace with a stainless steel heat exchanger to draw 100% fresh air from the outside, there would also be an exhaust fan interlocked with the furnace. The cfm output of the furnace and exhaust fan should be close in performance. An HRV can then be used on this to recover some of the cost running this system when its -40.
__________________
M2CW
Reply With Quote
  #5  
Old 08-30-2007, 08:54 PM
ponokareefer's Avatar
ponokareefer ponokareefer is offline
Member
 
Join Date: Jan 2007
Location: Ponoka, Alberta
Posts: 859
ponokareefer is on a distinguished road
Default

For whatever reason, our house is at 75 humidity as well and we are having problems as listed above. As we only have a 3 gallon tank in our house, the issue has to be other things. We are looking into getting a dehumidifier to help with the issues. From our research so far, Home Depot seems to have some at reasonable prices with quality names.
__________________
240 gallon tank build: http://www.canreef.com/vbulletin/sho...d.php?t=110073
Reply With Quote
  #6  
Old 08-30-2007, 08:58 PM
aussiefishy aussiefishy is offline
Member
 
Join Date: Nov 2003
Location: Calgary
Posts: 88
aussiefishy is on a distinguished road
Default

I think i will share my experiences.

Last winter was the first winter for my 350 gallons in my Townhouse. The humidity is really a problem, Condensation at the windows (turns to Ice at the window sills), Fallin ceiling paint and damp clothes.... that was what happened when you have -20C outside and a humidex of 60.

I bought a De-humidifier and that helps out alot. but the bad thing is the electricity bill, without the dehumidifier the bill already reach$2XX... with it on the billi was about $45-50 dollars more/month.

i think about the exhaust fan idea, but i ask a couple friends that are in the HVAC trades about it and they all think it is dangerous, because if you have a low power fan, it will not do much. if you use a high-powered exhaust fan blowing humid air out, some air has to come back inside your house, it can either come from your freshair intake OR your furnace exhaust -- very dangerous CO poisoning, and your gas bill WILL go WAY UP due to cold air coming in.

so i was recommended by others to try a HRV - heat recovery ventilator.

this unit i bought don't cost much to setup and it will do a few things for me.

1. bring a constant supply of fresh air from outside while heat is retained.
2. build in HEPA filter helps me breath a little easier especially if you have other pets.
3. remove excess humidity.

these in turn will lower my energy bills, my doctors bill and keep your family member happier - another example would be like choosing between a air conditioner(your family memebr enjoys it TOO) or a aquarium chiller(only your fish can enjoy).

This will be my first winter with a HRV so i am not sure will it perform the way i want it to, but it certainly solve most problems encounter by me.

just a 2 cents.
__________________
check it out! members.shaw.ca/aussiefishy
Reply With Quote
  #7  
Old 08-30-2007, 09:36 PM
TRS's Avatar
TRS TRS is offline
Member
 
Join Date: Feb 2003
Location: Lloydminster, Alberta
Posts: 408
TRS is on a distinguished road
Default

I would like to hear how you make out with the HRV this winter. Last fall I installed a Humidex unit (http://humidex.ca/index.htm) to replace my dehumidfier as well as its operating cost. It is quite cheap and easy to install. Have any others tried it? The Humidex unit is a very simple concept, drawing cool and moist air from the floor and venting it to the outdoors. It is very quiet and kept my humidity level between 40 - 60 percent all winter and throughout the dog days of summer. It is fine, but as I continue to add tanks to my fleet...the humidity will become more intense. The next step may be an HRV.
Reply With Quote
  #8  
Old 08-30-2007, 10:05 PM
fortheloveofcrabs fortheloveofcrabs is offline
Member
 
Join Date: Mar 2004
Location: Edmonton
Posts: 252
fortheloveofcrabs is on a distinguished road
Default

I don't mean to pry, but how much do these "HRV"'s cost? And where can you buy them?
__________________
_______________________________________

Have a good one!
Reply With Quote
  #9  
Old 08-30-2007, 10:26 PM
Delphinus's Avatar
Delphinus Delphinus is offline
Member
 
Join Date: Dec 2001
Location: Calgary
Posts: 12,896
Delphinus has a spectacular aura aboutDelphinus has a spectacular aura aboutDelphinus has a spectacular aura about
Send a message via MSN to Delphinus
Default

I've written about HRV's now several times on the board, I'll try to find the posts where I've done so, so that I can point to those as well.

Basically - the HRV will solve your humidity problems (assuming your outside air is less humid).

An exhaust fan will draw the air out - but if you don't replace the air going out, you have an air deficit. This can be a problem. First of all, it means your going to be heating your house more than you should. Secondly, if the house is too air tight then that air is going to come in through whatever means it can - and as Aussifishy pointed out - this can be a serious threat if if comes in through a furnace exhaust vent.

Stove top fans, for example, over a certain amount of cfm, building code requires that there be interlock with the furnace. Ie. if the fan is on, so too is the furnace.

I had BIG BIG humidity problems in my house. The HRV solved them. It runs on a dehumidistat (opposite of humidistat) so that if the humidity of the house EXCEEDS a threshold, the unit turns on. This keeps your household humidity in control.


Quote:
Originally Posted by Joe Reefer View Post
HRV's are only an option to reducing heating costs by recovering some of the heat being exhausted. To elimate moisture issues you must "exchange air" simple as that.

If you are truly serious about not having any moisture issues, a make-up air system should be considered. This would include a small furnace with a stainless steel heat exchanger to draw 100% fresh air from the outside, there would also be an exhaust fan interlocked with the furnace. The cfm output of the furnace and exhaust fan should be close in performance. An HRV can then be used on this to recover some of the cost running this system when its -40.
Not quite correct, Lando. The HRV is a heat exchanger AND an air exchanger. It pulls air out of the house, and draws air INTO the house.

You shouldn't need a second furnace - the HRV, if sized correctly, can and WILL solve the humidity problems.

Quote:
Originally Posted by phillybean View Post
What about dehumidifiers? I think I spelled that wrong but you know what I mean.

http://cgi.ebay.ca/Soleus-CFM40-Port...QQcmdZViewItem
They work, but they're noisy and the effect is localized. And as soon as they stop, the humidity goes right back up again. I ran one for years and it only helped reduce the problem but it did not eliminate the problem. The HRV did solve my wet windows/wet walls/mold/mildew problem.

Pricey yes, but ... it is littlesilvermax said. Once your house has black mold, you may as well burn it down. This is the reason that grow houses tend to be condemned - the humidity just ruins the house and it becomes a health hazard to those who live inside it. Our aquariums might not do the same amount of damage but, humidity is humidity. So pricey it may be, but if you have excessive humidity then it becomes the price to pay to stay within the hobby.

You can buy HRV's at Home Depot and install them yourself if you're handy with DIY. You can also call a HVAC place and have them do it.

I had a place recommended to me by another Canreefer and I would recommend the same people. They did an excellent analysis of the amount of humidity, the volume of the house, required turnovers, and came up with a unit sizing recommendation. Anyone in Calgary considering a HRV, PM me and I will give you the contact information.
__________________
-- Tony
My next hobby will be flooding my basement while repeatedly banging my head against a brick wall and tearing up $100 bills. Whee!
Reply With Quote
  #10  
Old 08-30-2007, 10:08 PM
Parker's Avatar
Parker Parker is offline
Member
 
Join Date: Aug 2005
Location: Edmonton
Posts: 1,012
Parker is on a distinguished road
Default

Thanks for the advice all. I have some time to sort this out, once the tank is drained from it's leak test it probably won't be filled again for close to a year.

However we are renovating our home at the moment and part of that renovation includes HVAC upgrades so tacking on a HRV at the same time would be a minimal cost.

Aussiefishy, do you have a brand name of the unit you chose?
__________________
Robb

Last edited by Parker; 08-30-2007 at 11:16 PM.
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 11:08 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.