![]() Hi
@Albert: Not all pumps can be dimmed by the reduction of the voltage (AC-side). It depends on the motor type, the pump-producer can give this information. If the pump is dimmable by reducing the mains voltage you will be able to control the pump with our new dimmable socket - coming soon. Vortech: I can't promis this feature at the moment. @Ginzo: That doesn't work. These USB-WLAN adapters are constructed for the PC-side, you can't connect it to ProfiLux. It's the same like connecting a USB-WLAN to a printer or other device - not possible. |
#352
|
|||||
|
|||||
![]() matthias,
question for you. with the new firmware is it possible to control more then 2 tunzes? just today i connected a third tunze to the system using the L1-L2 splitter but i realized that the controller only has the capability now to control 2 current pumps. what i mean by this is 2 of the 3 tunzes now are doing the same function in random mode. |
#353
|
||||
|
||||
![]() Quote:
Is it a bug in 3.01 (fixed in 3.02 maybe??) or is the problem in my unit? |
#354
|
||||
|
||||
![]() OK, the pulse lenght means maximum time for the pulse. I need to read better (and increase hysteresis)
![]() |
#355
|
||||
|
||||
![]() @niloc: at the moment only 2 pumps (or groups) can be controlled independently. I am not sure how to programm a mode for more than 2 pumps. Now it is easy - 2 pumps, one ebb, other flood and vv. But how can i program 3 or more pumps?
@jukka: i must be honest with you - firmware 3.01 has a little bug regarding the pulse/pause mode. Durations longer than 256s (damned BYTES and WORDS...) can't be calculated. From 3.02 this function is OK. |
#356
|
||||
|
||||
![]() Thanks Matthias,
Can we expect at some point an update to the firmware that will enable us to send an email when an alarm goes off..or an SMS ? Regards, Ginzo |
#357
|
||||
|
||||
![]() Now if somebody could only explain to me the "probe holder pieces" that came with my Profilux..I'm a little baffled at how to set them up ?
![]() |
#358
|
||||
|
||||
![]() Quote:
|
#359
|
||||
|
||||
![]() whoa ! would have taken me forever to figure that out !
Thanks for the post ! Here's the picture in question: ![]() |