Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > Reef

Reply
 
Thread Tools Display Modes
  #1  
Old 11-26-2006, 01:40 PM
Chad's Avatar
Chad Chad is offline
Member
 
Join Date: May 2003
Location: Surrey
Posts: 1,031
Chad is on a distinguished road
Default

I use the MCE600 on my 50gal. Its not overkill in my opinion.
__________________
Chad

Reply With Quote
  #2  
Old 11-26-2006, 03:50 PM
Buddyboy's Avatar
Buddyboy Buddyboy is offline
Member
 
Join Date: Aug 2005
Location: Vancouver, BC
Posts: 110
Buddyboy is on a distinguished road
Default

Something else to consider. The MCE300 is a brand new skimmer in the Deltec line and the bugs haven't been worked out of it yet. I have been following this thread about another reefers experiences:

http://www.reefcentral.com/forums/sh...hreadid=963923

Seems to be a mixed bag? On the plus side, it should be considerably cheaper than the MCE600 when they are available.

Or, you could also just splurge for the MCE600 if you have the $$$!
Reply With Quote
  #3  
Old 11-26-2006, 04:10 PM
Funky_Fish14's Avatar
Funky_Fish14 Funky_Fish14 is offline
Member
 
Join Date: Apr 2005
Location: (Close to) Millet, Alberta
Posts: 1,153
Funky_Fish14 is on a distinguished road
Send a message via MSN to Funky_Fish14
Default

I'd definetly go for the larger unit, because of all the reasons mentioned above. Upgrades in the future, etc... Or, say you have a mishap in the tank, something dies overnight. The larger skimmer will pull more out than the smaller, ofcourse. And you cant really overskim, just set it to skimmate that is more dry.

Which reminds me... I STILL havent set-up my deltec yet, cause I havent set-up the new system

Chris
__________________
No more tanks - Laying off the ReefCrack for awhile!
Cheers,
Chris
Reply With Quote
  #4  
Old 11-27-2006, 01:51 AM
Rippin Rippin is offline
Member
 
Join Date: Nov 2006
Location: Vancouver, B.C.
Posts: 209
Rippin is on a distinguished road
Default

Thanks for all of the replies and suggestions.

I decided to go with the MCE600 unit. Purchased and installed it today. Pretty much plug and play. I'm very happy with the noise level (or lack of). The pump is quite quiet. I can hear the air intake over the pump Much better (in terms or noise level) compared to the Prizm Pro.

Two things that I could nit-pick about.
1. The power cord is way too short! Forget about a drip loop. It needs to be double in length.
2. The collection cup should be transparent on both sides. I have the skimmer mounted to the side of my tank and it's difficult to see what's collecting in the cup and how high to adjust to create the proper skimmate consistency.
Reply With Quote
  #5  
Old 11-27-2006, 01:53 PM
Chad's Avatar
Chad Chad is offline
Member
 
Join Date: May 2003
Location: Surrey
Posts: 1,031
Chad is on a distinguished road
Default

yeah, I have the same complaints. Plus add to the clear intake which gums up nicely with coraline etc.

The collection cup and be turned around as well if you need to see the clear side.

But I am happy with its performance over all.. Beware it will FLOOD when you do water changes!!!!!!!!! Raise the collection cup after water changes for a good hour or so.
__________________
Chad

Reply With Quote
  #6  
Old 11-27-2006, 02:59 PM
Rippin Rippin is offline
Member
 
Join Date: Nov 2006
Location: Vancouver, B.C.
Posts: 209
Rippin is on a distinguished road
Default

Quote:
Originally Posted by Chad View Post
yeah, I have the same complaints. Plus add to the clear intake which gums up nicely with coraline etc.

The collection cup and be turned around as well if you need to see the clear side.

But I am happy with its performance over all.. Beware it will FLOOD when you do water changes!!!!!!!!! Raise the collection cup after water changes for a good hour or so.
Yes, I could turn around the collection cup, but then the overflow pipe would not have a nice hole to fit in

Also, how would this unit flood? The overflow pipe would prevent the level of the water from escaping the top lid.
Reply With Quote
  #7  
Old 11-27-2006, 05:59 PM
Chad's Avatar
Chad Chad is offline
Member
 
Join Date: May 2003
Location: Surrey
Posts: 1,031
Chad is on a distinguished road
Default

Really? Cuz mine has a hole on both sides. So you can turn it around.. If it doesn't it has to be a mistake. Its designed to go both ways.

Trust me.. that overflow pipe is worthless unless its just overflowing some skimate.. When the surface tension changes it overflows easily.
__________________
Chad


Last edited by Chad; 11-27-2006 at 06:06 PM.
Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 12:10 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.