![]() I have my saltwater tank on a dedicated 12 Amp circuit. Not sure 'two' separate ones are needed, if your power is out for example, it's out. I don't think your total load 'should' be more than 12 amps!
__________________
130 Gal Community Planted Tank and a 250Gal Peninsula FOWLR |
#2
|
|||||
|
|||||
![]() My logic is that its a good idea (building code) to have electrical devices that are exposed to water/moisture plugged into a GFCI receptacle. Unlike a regular breaker or fuse its pretty easy to trip a GFCI. So by splitting my water circulation pumps between two circuits I reduce the risk of my tank completely shutting down by 50% if there is some minor issue.
__________________
"We shall dive down through black abysses... and in that lair of the Deep Ones we shall dwell amidst wonder and glory forever." - H.P. Lovecraft Old 120gal Tank Journal New 225gal Tank Journal May 2010 TOTM The 10th Annual Prince George Reef Tank Tour |
#3
|
|||||
|
|||||
![]() Haven't done any measurements recently, but the spreadsheet I use to track items on my tank does include one on electrical. Here's a link should anyone be interested in doing the same. This has not been updated in a long time & some of the equipment is no longer in use, replaced by different gear. Fortunately hydro rates & service in my part of the country are still a bargain & reliable. Still looking at getting more self sufficient with utilities though, that includes solar, wind & collecting rain water, possibly setting up a grey water system in my home. Water rates are what kill me here. Vernon/NORD officials can't seem to figure out how to keep those rates reasonable. Ours are among the highest in the Okanagan.
https://docs.google.com/spreadsheets...it?usp=sharing If the goal here is to calculate cost, watts would be a better starting point than amps, since rates from the utilities are generally billed using kilowatt hours. If your power monitoring equipment provides the option to display watts, you save one step. Not long after they installed the smart meter on my house, I purchased a monitoring device that reports whole house usage. I used a plug in device to individually measure the power use of the items on the spreadsheet.
__________________
Mike 77g sumpless SW DIY 10 watt multi-chip LED build ![]() |
#4
|
|||||
|
|||||
![]() Quote:
Quote:
__________________
Mike 77g sumpless SW DIY 10 watt multi-chip LED build ![]() |
#5
|
|||||
|
|||||
![]() Quote:
__________________
130 Gal Community Planted Tank and a 250Gal Peninsula FOWLR |
#6
|
||||
|
||||
![]() Quote:
but after a power outage on a tank that big he will probably have 1200W of heaters and if the tank temp drops 5-6 degrees after a good outage, when power comes back on all the heater kick in pumps lights ect hes well over the 15A a regular circuit will handle. split everything evenly or at least have a powerhead and heater on a second circuit. My 250 I have both LED light fixtures a heater and a power head on one and then the apex on the other running everything else. the LED have their own controllers and they throw nothing for heat so I couldnt see using 2 apex outlets for them and i could care less if that circuit trips for any reason that the fish are in the dark until I could get there but if the 2nd circuit running EVERYTHING else blows I still have some heat ( not enough but it will probably give me hours and hours of extra time before the tank drops toooooo much in temp.) and circulation its not only about the power draw its also redundancy becuase anyone with any time invested in this hobby will testify bad sh*t never happens when your home its middle of the night or 10 min after you walk out the door to go to work. not ragging on you at all just food for thought!
__________________
250G DD LED SPS R.I.P. 180G LED SPS 80"x36". 300G custom build Owner of Mountain Ridge Heating and Gas Class A gas fitter, HVAC |
![]() |