#6
|
|||||
|
|||||
![]() So your programming would look like this
Fallback ON Set ON If FeedA 005 Then OFF If Time 10:00 to 10:15 Then OFF You probably should also set your power heads and skimmer to off as well. This is the simplest method. The method I used was to setup a virtual outlet and had it turn on and off at a certain time and had my pumps looking to see if it was on or off. Virtual Outlet: [Autofeed] Set OFF If Time 10:00 to 10:15 Then ON Outlet: [MainPump] Fallback ON Set ON If FeedA 005 Then OFF If Time 10:00 to 10:15 Then OFF If Outlet Autofeed = ON Then OFF**** It is simply the last line you would add to anything you want turned off at 10:00am. This programming method would also be nice if you wanted to change the feed time. You would only have to change it in one place. |