#1
|
|||||
|
|||||
Apex ATO Programming Help
I'm pretty new to the APEX programming.. I'm trying to setup my ATO programming and it seems to be working but I'm hesitant to leave it be without having someone else review the code. So here it is:
Setup is RODI with a Solenoid connected to the Avast Marine ATO. (Pressure Switch w/ backup float valve on RODI line into the tank) ATO_3_4 Fallback OFF Set OFF If Outlet ATO_ADD = ON Then ON ATO_ADD Set OFF If Switch1 CLOSED Then ON If Time 07:00 to 19:00 Then OFF Defer 001:00 Then ON ATO_HIGH Set OFF If Outlet ATO_ADD = ON Then ON Defer 010:00 Then ON ATO_LOW Set OFF If Switch1 CLOSED Then ON Defer 999:00 Then ON Email_ALM Set OFF If Temp > 80.5 Then ON If Temp < 77.0 Then ON If Outlet ATO_HIGH = ON Then ON If Outlet ATO_LOW = ON Then ON Is this functional? Basically it's adding only during the night and if the switch is closed (adding) for longer than 10 mins or doesn't call to top off for 999 mins then it alarms. Both conditions would indicate something isn't working properly. Is there a way to defer for longer than 999mins? Basically I wanted it to alarm if it didn't top off at all for 24 hours, or for longer than 10 mins. |