If you have a PRV it shouldn't be too far downstream from your water meter. If its the same Watts 25AUB, it wont' be difficult to adjust at all, in fact the spec sheet I pulled off the net says you should clean out the sediment screen from time to time. A wrench & screwdriver (pressure guage too I guess) is all you need to adjust the pressure. Loosen the locknut with the wrench, use screwdriver to turn the adjustment screw clockwise for more pressure, counterclockwise for reduced pressure. Once you have the desired pressure, tighten the locknut. Edit, might be two wrenches, not screwdriver. http://www.watts.com/pages/_products...ls.asp?pid=776