Quote:
Originally Posted by Canadian View Post
To properly cool a T5 fixture the air flow should be directed towards the labeled end of the lamp. Over cooling T5 lamps by randomly blasting them with a fan can actually reduce light output. Additionally, not protecting the reflectors on a Tek fixture with an acrylic shield is almost certain to cause pitting of the reflectors.
I did some fiddling around with this when I built my retrofit. I wanted to find some info on just how much the output of my lamps was being reduced by not actively cooling them. I found an IR thermometer that could take accurate temps of the bulbs, searched around until I found a PDF that showed a the lumen output vs temp. Then I found out that all this effort showed me that I was losing a whole 7% running my bulbs without active cooling. This probably varies with different bulbs a bit so it's a guess but as you can imagine I did not feel it was time sell spent.

The sweet spot for your bulb is 35C. I measured the Tek lights at work at 50c or so so that's going to cost you about 12%. Cooling your bulb past 25C will cost you just as much output so you really need a rheostat to control the fans if you're serious about this.

Additionally I found it very difficult to cool the bulbs without some sort of shield around them to channel the air like the acrylics that are available for the Tek fixtures. I don't know what kind of acrylic they make those out of but it isn't very expensive so it's bound to block some light. Get a little salt spray on it or even worse clean it with some windex and a nice abrasive paper towel and I bet you'd have no problem decreasing your output by the same 12%.

I don't mean to single out Canadian with this, if you ask about T5s on any reef site people will tell you about decreased output without active cooling but nobody ever has any friggin numbers!
Reply With Quote
 


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 10:04 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.