Canreef Aquatics Bulletin Board  

Go Back   Canreef Aquatics Bulletin Board > General > DIY

 
 
Thread Tools Display Modes
Prev Previous Post   Next Post Next
  #6  
Old 12-19-2008, 11:56 PM
fkshiu's Avatar
fkshiu fkshiu is offline
Member
 
Join Date: Sep 2005
Location: Vancouver, BC
Posts: 1,499
fkshiu is on a distinguished road
Default

Interesting idea, although I am having a bit of trouble conceptualizing how you would prevent most of the water from going down the larger emergency drain during normal operation.

If you somehow designed some kind of a weir that directed the water only into the smaller interior drain, there may be some difficulty with tuning since you'd have trouble see how close the interior drain was to being "full". In a standard Herbie this is easy because you can observe the water level in the overflow space. It would be difficult to do the same in your design. You can't even observe which pipe (inside or outside) the water is exiting from in the sump since a truly silent herbie requires the drain pipes to be submerged in the sump.
Reply With Quote
 


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 05:04 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.