![]() Okay get ready for it... AHHHHHH! I'll add some notes to say what everything does.
PUM#-A01 -------- Main return pump LT1$-A02 ---------- Metal halide LT2$-A03 --------- Metal halide CO2&-A05 -------- CO2 solenoid for calcium reactor COL%-A06 ---------- Cooling fan KAL#-A07 -------- Kalk reactor mixing pump ALM&-A08 ------- Audible, email and text alarm LT3$-A09 --------- Refugium light HET%-A10 -------- Heater SKM#-A11 -------- Protein skimmer feed pump ATO#-A13 -------- Tunze Osmolator auto top off (so that lights have time to cool after a power interruption) If Power 020 Then LT1 OFF If Power 020 Then LT2 OFF (defaults) If Time > 00:00 Then PUM ON If Time > 00:00 Then ALM OFF If Time > 00:00 Then ATO ON If Time > 00:00 Then SKM ON (so that lights and tank have time to cool if tank gets too warm and controller shuts off lights) Max Change 020 M Then LT1 OFF Max Change 020 M Then LT2 OFF (seasonal lighting control) If Sun 000/-120 Then LT1 ON If Sun 060/-060 Then LT2 ON (reverse lighting for refugium light) If Sun 000/-060 Then LT3 OFF (seasonal cooling and heating control) If Temp > RT+1.8 Then COL ON If Temp < RT+1.5 Then COL OFF If Temp < RT+1.2 Then HET ON If Temp > RT+1.5 Then HET OFF (safety precautions in case tank becomes to warm or too cold) If Temp > RT+3.5 Then LT1 OFF If Temp > RT+3.5 Then LT2 OFF If Temp > RT+3.5 Then ALM ON If Temp < RT+-0.5 Then ALM ON (in case of temperature probe failure) If Temp < RT+-9.9 Then HET OFF (kalk reactor mixing pump mixes for 5 minutes 4 times a day) OSC 005/255 ON/OFF Then KAL OFF (calcium reactor pH control) If pH2 > 06.60 Then CO2 ON If pH2 < 06.50 Then CO2 OFF (tank pH control) If pH < 07.60 Then CO2 OFF If pH < 07.60 Then ALM ON If pH > 08.40 Then ALM ON If pH > 08.30 Then ATO OFF (water on the floor sensor: open means dry and closed means wet) If Switch1 OPEN Then PUM ON If Switch1 OPEN Then SKM ON If Switch1 CLOSED Then SKM OFF If Switch1 CLOSED Then PUM OFF If Switch1 CLOSED Then ATO OFF If Switch1 CLOSED Then ALM ON (I have a single overflow hole in my tank so I have a switch mounted on the rim to stop potential overflows onto the floor. Open means the water level is too high and closed means everything is fine) If Switch2 OPEN Then PUM OFF If Switch2 CLOSED Then PUM ON If Switch2 OPEN Then ALM ON Any questions?
__________________
"We shall dive down through black abysses... and in that lair of the Deep Ones we shall dwell amidst wonder and glory forever." - H.P. Lovecraft Old 120gal Tank Journal New 225gal Tank Journal May 2010 TOTM The 10th Annual Prince George Reef Tank Tour Last edited by whatcaneyedo; 02-09-2010 at 11:41 PM. |
Thread Tools | |
Display Modes | |
|
|